Literature DB >> 24930135

Extended use of the GuideLiner in complex coronary interventions.

Pak Hei Chan1, Eduardo Alegria-Barrero, Nicholas Foin, Manuel Paulo, Alistair C Lindsay, Nicola Viceconte, Carlo Di Mario.   

Abstract

AIMS: Challenging coronary anatomies including chronic total occlusions (CTO), extreme vessel tortuosity, diseased bypass grafts, and anomalous coronary arteries pose difficulties in coronary interventions. The GuideLiner is a monorail catheter originally developed to facilitate delivery of stents to target lesions in tortuous vessels. We conducted a study on the feasibility and safety of utilising this catheter in a wider array of complex coronary interventions. METHODS AND
RESULTS: Consecutive patients undergoing coronary or peripheral interventions where a GuideLiner was used were recruited into this study. Patient demographics, lesion and vessel characteristics, procedural details and outcomes were prospectively entered into our database and analysed. From September 2009 to October 2011, 54 consecutive patients underwent coronary intervention in our institution using a GuideLiner; 21 out of 54 coronary applications were motivated by the need to increase support to cross CTOs, predominantly of the RCA. Anomalous or angulated take-off of the treatment vessels (31%), previously deployed proximal stents (15%), heavy proximal calcification (9%) and tortuosity (7%) accounted for the remaining reasons. One patient had successful renal denervation with the aid of a GuideLiner catheter. Procedural success was 98% in our series with no device-related periprocedural complications such as ostial dissection or myocardial necrosis.
CONCLUSIONS: The use of a GuideLiner facilitates the approach to complex coronary interventions including chronic total occlusion and saphenous vein graft intervention by providing greater back-up support and easier engagement of coronary ostia.

Entities:  

Mesh:

Year:  2015        PMID: 24930135     DOI: 10.4244/EIJY14M06_02

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  11 in total

1.  The Efficacy and Safety of Using Extension Catheters in Complex Coronary Interventions: A Single Center Experience.

Authors:  Mu-Shiang Huang; Chun-I Wu; Fu-Hsiang Chang; Hsien-Yuan Chang; Po-Tseng Lee; Ju-Yi Chen; Wen-Huang Lee; Chih-Chan Lin; Shih-Hung Chan; Ping-Yen Liu; Cheng-Han Lee
Journal:  Acta Cardiol Sin       Date:  2017-09       Impact factor: 2.672

2.  Ultrathin (60 μm), ultralong (≥40 mm) sirolimus-eluting stent: study of clinical and safety profiles among real-world patients.

Authors:  Santosh Kumar Sinha; Puneet Aggarwal; Umeshwar Pandey; Mahmodullah Razi; Awdesh Kumar; Vinay Krishna
Journal:  Anatol J Cardiol       Date:  2021-02       Impact factor: 1.596

3.  Clinical Outcomes of Polytetrafluoroethylene-Covered Stents for Coronary Artery Perforation in Elderly Patients Undergoing Percutaneous Coronary Interventions.

Authors:  Huang-Joe Wang; Jen-Jyh Lin; Wan-Yu Lo; Chih-Ping Chang; Chung-Ho Hsu; Li-Chuan Hsieh; Yeh-Peng Chen; Yen-Nien Lin; Kuan-Cheng Chang; Ping-Han Lo
Journal:  Acta Cardiol Sin       Date:  2017-11       Impact factor: 2.672

4.  Are catheter extension devices one step forward for complex coronary interventions?

Authors:  Sergio García-Blas; Julio Núñez
Journal:  Anatol J Cardiol       Date:  2016-05       Impact factor: 1.596

5.  Citius, Altius, Fortius: The impact of guide catheter extensions in contemporary percutaneous coronary intervention.

Authors:  Georgios E Christakopoulos; Emmanouil Brilakis
Journal:  Anatol J Cardiol       Date:  2016-05       Impact factor: 1.596

6.  From debulking to delivery: sequential use of rotational atherectomy and Guidezilla™ for complex saphenous vein grafts intervention.

Authors:  Mariano Pellicano; Vincent Floré; Emanuele Barbato; Bernard De Bruyne
Journal:  BMC Cardiovasc Disord       Date:  2018-06-19       Impact factor: 2.298

7.  The Safety and Efficacy of Guidezilla Catheter (Mother-in-Child Catheter) in Complex Coronary Interventions: An Observational Study.

Authors:  Prakash Kumar; Puneet Aggarwal; Santosh Kumar Sinha; Dibbendu Khanra; Mahmodullah Razi; Awdesh Kumar Sharma; Ramesh Thakur; Umeshwar Pandey; Vinay Krishna
Journal:  Cardiol Res       Date:  2019-11-24

8.  Application of a rapid exchange extension catheter technique in type B2/C nonocclusive coronary intervention via a transradial approach.

Authors:  Hong-Chao Wang; Wei Lu; Zi-Han Gao; Ya-Nan Xie; Jie Hao; Jin-Ming Liu
Journal:  World J Clin Cases       Date:  2021-04-26       Impact factor: 1.337

9.  Did the use of the Guideliner V2(TM) guide catheter extension increase complications? A review of the incidence of complications related to the use of the V2 catheter, the influence of right brachiocephalic arterial anatomy and the redesign of the V3(TM) Guideliner and clinical outcomes.

Authors:  Mohammad Alkhalil; Alison Smyth; Simon J Walsh; Conor McQuillan; Mark S Spence; Colum G Owens; Colm G Hanratty
Journal:  Open Heart       Date:  2016-01-27

10.  Early clinical experience with Guidezilla for transradial interventions in China.

Authors:  Min Ma; Kai-Yue Diao; Xiao-Jing Liu; Yong He
Journal:  Sci Rep       Date:  2018-04-03       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.