Pupil-expansion ring implantation through a 0.9 mm incision.

Suven Bhattacharjee1.   

Abstract

UNLABELLED: Disposable square and hexagonal Bhattacharjee pupil-expansion rings are made of 5-0 nylon, have notches at the corners, and flanges at the sides in a single 0.1 mm thin plane. To insert the ring, a flange is held with a 23-gauge forceps and the ring is inserted through a 0.9 mm (20-gauge) or larger main- or side-port incision. Alternate flanges are tucked under the iris using a Kuglen hook. A 23-gauge forceps and an iris hook can also be used to tuck the flanges bimanually. The ring is removed by disengaging 2 notches and pulling it out of a 0.9 mm (20-gauge) incision. No snagging of the incision occurs at insertion or removal. No injector is required. The device is useful in standard coaxial phacoemulsification, femtosecond laser-assisted cataract surgery, biaxial microincision cataract surgery (MICS), coaxial sub-2.0 mm MICS, and small-pupil microincision vitreous surgery and in eyes with shallow anterior chambers. FINANCIAL DISCLOSURE: Dr. Bhattacharjee has a pending international patent application (PCT-WIPO) for the pupil-expansion devices.
Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24928337     DOI: 10.1016/j.jcrs.2014.05.003

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

1.  Femtosecond laser-assisted cataract surgery in small pupils using non-aligned iris expansion ring without viscoelastic and corneal suture.

Authors:  Bernardo Franco de Carvalho Tom Back; Pedro Rezende Henriques; Senice Alvarenga Rodrigues Silva; Richard Yudi Hida
Journal:  Int Ophthalmol       Date:  2021-11-10       Impact factor: 2.031

2.  B-Hex, an ace up the sleeve for small pupil phacoemulsification.

Authors:  Rimsha Sarosh; Omar Rashid
Journal:  Rom J Ophthalmol       Date:  2022 Jan-Mar

3.  B-HEX pupil expander: Pupil expansion redefined.

Authors:  Suven Bhattacharjee
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

Review 4.  Cataract surgery in small pupils.

Authors:  Boris Malyugin
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

5.  B-HEX pupil expander in vitreoretinal surgery - A case series.

Authors:  Debdulal Chakraborty; Ayan Mohanta; Arup Bhaumik
Journal:  Indian J Ophthalmol       Date:  2020-06       Impact factor: 1.848