Literature DB >> 24927118

Bispectral index guided titration of sevoflurane in on-pump cardiac surgery reduces plasma sevoflurane concentration and vasopressor requirements: a prospective, controlled, sequential two-arm clinical study.

Rainer Nitzschke1, Joana Wilgusch, Jan F Kersten, Constantin J Trepte, Sebastian A Haas, Daniel A Reuter, Matthias S Goepfert.   

Abstract

BACKGROUND: Electroencephalographic-based monitoring systems such as the bispectral index (BIS) may reduce anaesthetic overdose rates.
OBJECTIVE: We hypothesised that goal-directed sevoflurane administration (guided by BIS monitoring) could reduce the sevoflurane plasma concentration (SPC) and intraoperative vasopressor doses during on-pump cardiac surgery.
DESIGN: A prospective, controlled, sequential two-arm clinical study.
SETTING: German university medical centre with more than 2500 cardiac surgery interventions per year. PATIENTS: Sixty elective on-pump cardiac surgery patients. INTERVENTION: In group Sevo1.8% (n = 29), the sedation depth was maintained with a sustained inspired concentration of sevoflurane 1.8% before and during cardiopulmonary bypass (CPB). In group SevoBIS (n = 31), the inspired sevoflurane concentration was titrated to maintain a BIS target between 40 and 60. OUTCOME MEASURES: SPC during CPB and the intraoperative administration of noradrenaline. Additional analyses were performed on intraoperative awareness, postoperative blood lactate concentration, duration of mechanical ventilation, intensive care unit length of stay and kidney injury.
RESULTS: Mean inspired sevoflurane concentration was 0.8% in group SevoBIS, representing a 57.1% reduction (P < 0.001) compared with group Sevo1.8%. The mean SPC was 42.3 μg ml(-1) [95% confidence interval (CI) 40.0 to 44.6] in group Sevo1.8% and 21.0 μg ml(-1) (95% CI 18.8 to 23.3) in group SevoBIS, representing a 50.2% reduction (P < 0.001). During CPB, the mean cumulative dose of noradrenaline administered was 13.48 μg kg(-1) (95% CI 10.52 to 17.19) in group Sevo1.8% and 4.06 μg kg(-1) (95% CI 2.67 to 5.97) in group SevoBIS (P < 0.001). Pearson's correlation coefficient (between the cumulative applied dosage of sevoflurane calculated from the area under the curve of the SPC over time and the administered cumulative noradrenaline dose) was 0.607 (P < 0.001). No intraoperative awareness signs were detected.
CONCLUSION: BIS-guided titration of sevoflurane reduces the SPC and decreases noradrenaline administration compared with routine care during on-pump cardiac surgery.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24927118     DOI: 10.1097/EJA.0000000000000106

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  6 in total

1.  Intraoperative reduction of vasopressors using processed electroencephalographic monitoring in patients undergoing elective cardiac surgery: a randomized clinical trial.

Authors:  C Sponholz; C Schuwirth; L Koenig; H Hoyer; S M Coldewey; C Schelenz; T Doenst; A Kortgen; M Bauer
Journal:  J Clin Monit Comput       Date:  2019-02-19       Impact factor: 2.502

Review 2.  Bispectral index for improving anaesthetic delivery and postoperative recovery.

Authors:  Yodying Punjasawadwong; Aram Phongchiewboon; Nutchanart Bunchungmongkol
Journal:  Cochrane Database Syst Rev       Date:  2014-06-17

3.  Effects of sevoflurane increments on left ventricular systolic long-axis performance during sevoflurane-remifentanil anesthesia for cardiovascular surgery.

Authors:  Won-Kyoung Kwon; Tae-Yun Sung; Ga-Yon Yu; Hanafi Sidik; Woon-Seok Kang; Younsuk Lee; Tae-Yop Kim
Journal:  J Anesth       Date:  2015-11-17       Impact factor: 2.078

4.  Bispectral index for improving intraoperative awareness and early postoperative recovery in adults.

Authors:  Sharon R Lewis; Michael W Pritchard; Lizzy J Fawcett; Yodying Punjasawadwong
Journal:  Cochrane Database Syst Rev       Date:  2019-09-26

5.  Relationship between Sevoflurane Plasma Concentration, Clinical Variables and Bispectral Index Values during Cardiopulmonary Bypass.

Authors:  Rainer Nitzschke; Joana Wilgusch; Jan Felix Kersten; Matthias Sebastian Goepfert
Journal:  PLoS One       Date:  2015-08-27       Impact factor: 3.240

6.  Isoflurane's Effect on Intraoperative Systolic Left Ventricular Performance in Cardiac Valve Surgery Patients.

Authors:  Ju Deok Kim; Ilsoon Son; Won Kyoung Kwon; Tae Yun Sung; Hanafi Sidik; Karam Kim; Hyun Kang; Jiyon Bang; Gwi Eun Yeo; Dong Kyu Lee; Tae Yop Kim
Journal:  J Korean Med Sci       Date:  2018-01-22       Impact factor: 2.153

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.