Literature DB >> 24924217

Evaluation of oscillometric and Doppler ultrasonic devices for blood pressure measurements in anesthetized and conscious dogs.

Catherine Vachon1, Marie C Belanger2, Patrick M Burns2.   

Abstract

Two non-invasive blood pressure (NIBP) devices (oscillometry and Doppler) were compared to invasive blood pressure using a Bland-Altman analysis, in anesthetized and conscious dogs. When considering the systolic arterial pressure only during general anesthesia, both NIBP devices slightly underestimated the systolic arterial blood pressure however the precision and the limits of agreement for the Doppler were of a greater magnitude. This indicates a worse clinical performance by the Doppler. The performance of both NIBP devices deteriorated as measured in conscious animals. In general, for the oscillometric device, determination of invasive diastolic and mean arterial pressures was better than the invasive systolic arterial pressure. Overall, the oscillometric device satisfied more of the criteria set by the American College of Veterinary Internal Medicine consensus statement. Based upon these results, the oscillometric device is more reliable than the Doppler in the determination of blood pressure in healthy medium to large breed dogs.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Anesthetized; Blood pressure measurement; Conscious; Dogs; Doppler; Oscillometry; petMAP®

Mesh:

Year:  2014        PMID: 24924217     DOI: 10.1016/j.rvsc.2014.05.003

Source DB:  PubMed          Journal:  Res Vet Sci        ISSN: 0034-5288            Impact factor:   2.534


  13 in total

1.  Tramadol does not enhance sedation induced by acepromazine in dogs.

Authors:  Eduardo R Monteiro; Renan B Lobo; Juarez S Nunes; Julia P P Rangel; Flavia S Bitti
Journal:  Can J Vet Res       Date:  2016-10       Impact factor: 1.310

Review 2.  Basics of monitoring equipment.

Authors:  Tanya Duke-Novakovski
Journal:  Can Vet J       Date:  2017-11       Impact factor: 1.008

3.  Constant-Rate Infusion of Dexmedetomidine to Manage Thiopental Anesthesia during Intracranial Surgery in Cynomolgus Macaques (Macaca fascicularis).

Authors:  Noemi Romagnoli; Alessandra Buonacucina; Carlotta Lambertini; Domenico Ventrella; Angelo Peli
Journal:  J Am Assoc Lab Anim Sci       Date:  2016-11       Impact factor: 1.232

4.  Effects of various factors on Doppler flow ultrasonic radial and coccygeal artery systolic blood pressure measurements in privately-owned, conscious dogs.

Authors:  Allison P Mooney; Dianne I Mawby; Joshua M Price; Jacqueline C Whittemore
Journal:  PeerJ       Date:  2017-03-22       Impact factor: 2.984

5.  Prevalence and risk factors associated with systemic hypertension in dogs with spontaneous hyperadrenocorticism.

Authors:  Paula García San José; Carolina Arenas Bermejo; Irene Clares Moral; Pedro Cuesta Alvaro; María Dolores Pérez Alenza
Journal:  J Vet Intern Med       Date:  2020-07-02       Impact factor: 3.333

6.  Echocardiographic estimation of left ventricular-arterial coupling in dogs with myxomatous mitral valve disease.

Authors:  Tatsuyuki Osuga; Tomoya Morita; Noboru Sasaki; Keitaro Morishita; Hiroshi Ohta; Mitsuyoshi Takiguchi
Journal:  J Vet Intern Med       Date:  2021-01-13       Impact factor: 3.175

7.  Impact of equipment and handling on systolic blood pressure measurements in conscious dogs in an animal hospital environment.

Authors:  Maria Lyberg; Ingrid Ljungvall; Jens Häggström; Ellinor Ahlund; Lena Pelander
Journal:  J Vet Intern Med       Date:  2021-02-15       Impact factor: 3.333

8.  ACVIM consensus statement: Guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats.

Authors:  Mark J Acierno; Scott Brown; Amanda E Coleman; Rosanne E Jepson; Mark Papich; Rebecca L Stepien; Harriet M Syme
Journal:  J Vet Intern Med       Date:  2018-10-24       Impact factor: 3.333

9.  Acute effect of ivabradine on heart rate and myocardial oxygen consumption in dogs with asymptomatic mitral valve degeneration.

Authors:  Prapawadee Pirintr; Vudhiporn Limprasutr; Nakkawee Saengklub; Parnpradub Pavinadol; Napat Yapao; Natthakarn Limvanicharat; Hathaisiri Kuecharoen; Anusak Kijtawornrat
Journal:  Exp Anim       Date:  2018-05-14

10.  Dynamic changes in intramedullary pressure 72 hours after spinal cord injury.

Authors:  Xin Zhang; Chang-Bin Liu; De-Gang Yang; Chuan Qin; Xue-Chao Dong; Da-Peng Li; Chao Zhang; Yun Guo; Liang-Jie Du; Feng Gao; Ming-Liang Yang; Jian-Jun Li
Journal:  Neural Regen Res       Date:  2019-05       Impact factor: 5.135

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.