Literature DB >> 24921532

Ring artifact correction using detector line-ratios in computed tomography.

Younguk Kim, Jongduk Baek, Dosik Hwang.   

Abstract

Ring artifacts in computed tomography (CT) images degrade image quality and obscure the true shapes of objects. While several correction methods have been developed, their performances are often task-dependent and not generally applicable. Here, we propose a novel method to reduce ring artifacts by calculating the ratio of adjacent detector elements in the projection data, termed the line-ratio. Our method estimates the sensitivity of each detector element and equalizes them in sinogram space. As a result, the stripe pattern can be effectively removed from sinogram data, thereby also removing ring artifacts from the reconstructed CT image. Numerical simulations were performed to evaluate and compare the performance of our method with that of conventional methods. We also tested our method experimentally and demonstrated that our method has superior performance to other methods.

Year:  2014        PMID: 24921532     DOI: 10.1364/OE.22.013380

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  6 in total

1.  Importance of CT image normalization in radiomics analysis: prediction of 3-year recurrence-free survival in non-small cell lung cancer.

Authors:  Doohyun Park; Daejoong Oh; MyungHoon Lee; Shin Yup Lee; Kyung Min Shin; Johnson Sg Jun; Dosik Hwang
Journal:  Eur Radiol       Date:  2022-05-31       Impact factor: 5.315

2.  Sparsity-based method for ring artifact elimination in computed tomography.

Authors:  Mona Selim; Essam A Rashed; Mohammed A Atiea; Hiroyuki Kudo
Journal:  PLoS One       Date:  2022-06-28       Impact factor: 3.752

3.  A Convex Reconstruction Model for X-ray Tomographic Imaging with Uncertain Flat-fields.

Authors:  Hari Om Aggrawal; Martin S Andersen; Sean Rose; Emil Y Sidky
Journal:  IEEE Trans Comput Imaging       Date:  2017-07-04

4.  Direct information retrieval after 3D reconstruction in grating-based X-ray phase-contrast computed tomography.

Authors:  Zhao Wu; Kun Gao; Zhili Wang; Chenxi Wei; Faiz Wali; Guibin Zan; Wenbin Wei; Peiping Zhu; Yangchao Tian
Journal:  J Synchrotron Radiat       Date:  2018-06-27       Impact factor: 2.616

5.  Complete Ring Artifacts Reduction Procedure for Lab-Based X-ray Nano CT Systems.

Authors:  Jakub Šalplachta; Tomáš Zikmund; Marek Zemek; Adam Břínek; Yoshihiro Takeda; Kazuhiko Omote; Jozef Kaiser
Journal:  Sensors (Basel)       Date:  2021-01-01       Impact factor: 3.576

6.  Principles for an Implementation of a Complete CT Reconstruction Tool Chain for Arbitrary Sized Data Sets and Its GPU Optimization.

Authors:  Jürgen Hofmann; Alexander Flisch; Robert Zboray
Journal:  J Imaging       Date:  2022-01-15
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.