Literature DB >> 24914074

Comparison of different intubation techniques performed inside a moving ambulance: a manikin study.

K B Wong1, C T Lui1, William Y W Chan2, T L Lau3, Simon Y H Tang1, K L Tsui2.   

Abstract

OBJECTIVE. Airway management and endotracheal intubation may be required urgently when a patient deteriorates in an ambulance or aircraft during interhospital transfer or in a prehospital setting. The objectives of this study were: (1) to compare the effectiveness of conventional intubation by Macintosh laryngoscope in a moving ambulance versus that in a static ambulance; and (2) to compare the effectiveness of inverse intubation and GlideScope laryngoscopy with conventional intubation inside a moving ambulance. DESIGN. Comparative experimental study. SETTING. The experiment was conducted in an ambulance provided by the Auxiliary Medical Service in Hong Kong. PARTICIPANTS. A group of 22 doctors performed endotracheal intubation on manikins with Macintosh laryngoscope in a static and moving ambulance. In addition, they performed conventional Macintosh intubation, inverse intubation with Macintosh laryngoscope, and GlideScope intubation in a moving ambulance in both normal and simulated difficult airways. MAIN OUTCOME MEASURES. The primary outcome was the rate of successful intubation. The secondary outcomes were time taken for intubation, subjective glottis visualisation grading, and eventful intubation (oesophageal intubation, intubation time >60 seconds, and incisor breakage) with different techniques or devices. RESULTS. In normal airways, conventional Macintosh intubation in a static ambulance (95.5%), conventional intubation in a moving ambulance (95.5%), as well as GlideScope intubation in a moving ambulance (95.5%) were associated with high success rates; the success rate of inverse intubation was comparatively low (54.5%; P=0.004). In difficult airways, conventional Macintosh intubation in a static ambulance (86.4%), conventional intubation in a moving ambulance (90.9%), and GlideScope intubation in a moving ambulance (100%) were associated with high success rates; the success rate of inverse intubation was comparatively lower (40.9%; P=0.034). CONCLUSIONS. En-route intubation in an ambulance by conventional Macintosh laryngoscopy is superior to inverse intubation unless the cephalad access is impossible. GlideScope laryngoscopy appears to be associated with lower rates of eventful intubation in difficult airways and has better laryngoscopic view versus inverse intubation.

Entities:  

Keywords:  Ambulances; Intubation; Laryngoscopes; Manikins

Mesh:

Year:  2014        PMID: 24914074     DOI: 10.12809/hkmj134168

Source DB:  PubMed          Journal:  Hong Kong Med J        ISSN: 1024-2708            Impact factor:   2.227


  3 in total

1.  A Randomized Comparison Simulating Face to Face Endotracheal Intubation of Pentax Airway Scope, C-MAC Video Laryngoscope, Glidescope Video Laryngoscope, and Macintosh Laryngoscope.

Authors:  Hyun Young Choi; Young Min Oh; Gu Hyun Kang; Hyunggoo Kang; Yong Soo Jang; Wonhee Kim; Euichung Kim; Young Soon Cho; Hyukjoong Choi; Hyunjong Kim; Gyoung Yong Kim
Journal:  Biomed Res Int       Date:  2015-06-16       Impact factor: 3.411

2.  Can the ETView VivaSight SL Rival Conventional Intubation Using the Macintosh Laryngoscope During Adult Resuscitation by Novice Physicians?: A Randomized Crossover Manikin Study.

Authors:  Andrzej Kurowski; Lukasz Szarpak; Zenon Truszewski; Lukasz Czyzewski
Journal:  Medicine (Baltimore)       Date:  2015-05       Impact factor: 1.889

3.  Comparison of the airway access skills of prehospital staff in moving and stationary ambulance simulation: A randomized crossover study.

Authors:  Onur Karaca; Basak Bayram; Nese Colak Oray; Asli Acerer; Zeynep Sofuoglu
Journal:  Turk J Emerg Med       Date:  2017-03-23
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.