PURPOSE: To assess the utility of a self-paced maximal oxygen uptake (VO2max) test (SPV) in eliciting an accurate measure of VO2max in comparison with a traditional graded exercise test (GXT) during motorized treadmill exercise. DESIGN: This was a cross-sectional experimental study whereby recreationally trained men (n = 13, 25.5 ± 4.6 y) completed 2 maximal exercise tests (SPV, GXT) separated by a 72-h recovery period. METHODS: The GXT was continuous and incremental, with prescribed 1-km/h increases every 2 min until the attainment of VO2max. The SPV consisted of 5 × 2-min stages of incremental exercise, which were self-selected and adjusted according to 5 prescribed RPE levels (RPE 11, 13, 15, 17, and 20). RESULTS: Although no significant differences in VO2max were observed between the SPV and GXT (63.9 ± 3.3 cf 60.9 ± 4.6 mL · kg-1 · min-1, respectively, P > .05), the apparent 4.7% mean difference may be practically important. The 95% limits-of-agreement analysis was 3.03 ± 11.49 mL · kg-1 · min-1. Therefore, in the worst-case scenario, the GXT may underestimate measured VO2max as ascertained by the SPV by up to 19%. Conversely, the SPV could underestimate the GXT by 14%. CONCLUSIONS: The current study has shown that the SPV is an accurate measure of VO2max during exercise on a motorized treadmill and may provide a slightly higher VO2max value than that obtained from a traditional GXT. The higher VO2max during the SPV may be important when prescribing training or monitoring athlete progression.
PURPOSE: To assess the utility of a self-paced maximal oxygen uptake (VO2max) test (SPV) in eliciting an accurate measure of VO2max in comparison with a traditional graded exercise test (GXT) during motorized treadmill exercise. DESIGN: This was a cross-sectional experimental study whereby recreationally trained men (n = 13, 25.5 ± 4.6 y) completed 2 maximal exercise tests (SPV, GXT) separated by a 72-h recovery period. METHODS: The GXT was continuous and incremental, with prescribed 1-km/h increases every 2 min until the attainment of VO2max. The SPV consisted of 5 × 2-min stages of incremental exercise, which were self-selected and adjusted according to 5 prescribed RPE levels (RPE 11, 13, 15, 17, and 20). RESULTS: Although no significant differences in VO2max were observed between the SPV and GXT (63.9 ± 3.3 cf 60.9 ± 4.6 mL · kg-1 · min-1, respectively, P > .05), the apparent 4.7% mean difference may be practically important. The 95% limits-of-agreement analysis was 3.03 ± 11.49 mL · kg-1 · min-1. Therefore, in the worst-case scenario, the GXT may underestimate measured VO2max as ascertained by the SPV by up to 19%. Conversely, the SPV could underestimate the GXT by 14%. CONCLUSIONS: The current study has shown that the SPV is an accurate measure of VO2max during exercise on a motorized treadmill and may provide a slightly higher VO2max value than that obtained from a traditional GXT. The higher VO2max during the SPV may be important when prescribing training or monitoring athlete progression.
Authors: Paula F Sperlich; Hans-Christer Holmberg; Jennifer L Reed; Christoph Zinner; Joachim Mester; Billy Sperlich Journal: J Sports Sci Med Date: 2015-05-08 Impact factor: 2.988
Authors: Nicholas J Hanson; Cory M Scheadler; Taylor L Lee; Noah C Neuenfeldt; Timothy J Michael; Michael G Miller Journal: Eur J Appl Physiol Date: 2016-05-05 Impact factor: 3.078
Authors: Nicholas J Hanson; Carter R Reid; Kaitlin M Cornwell; Taylor L Lee; Cory M Scheadler Journal: Eur J Appl Physiol Date: 2017-06-05 Impact factor: 3.078
Authors: Nicholas M Beltz; Ann L Gibson; Jeffrey M Janot; Len Kravitz; Christine M Mermier; Lance C Dalleck Journal: J Sports Med (Hindawi Publ Corp) Date: 2016-12-25
Authors: Verena Menz; Martin Niedermeier; Rainer Stehle; Hendrik Mugele; Martin Faulhaber Journal: Int J Environ Res Public Health Date: 2021-06-30 Impact factor: 3.390