Literature DB >> 24909769

Speciation of chromium using chronoamperometric biosensors based on screen-printed electrodes.

Ana Calvo-Pérez1, Olga Domínguez-Renedo2, M Asunción Alonso-Lomillo3, M Julia Arcos-Martínez4.   

Abstract

Chronoamperometric assays based on tyrosinase and glucose oxidase (GOx) inactivation have been developed for the monitoring of Cr(III) and Cr(VI). Tyrosinase was immobilized by crosslinking on screen-printed carbon electrodes (SPCEs) containing tetrathiafulvalene (TTF) as electron transfer mediator. The tyrosinase/SPC(TTF)E response to pyrocatechol is inhibited by Cr(III). This process, that is not affected by Cr(VI), allows the determination of Cr(III) with a capability of detection of 2.0±0.2 μM and a reproducibility of 5.5%. GOx modified screen-printed carbon platinised electrodes (SPCPtEs) were developed for the selective determination of Cr(VI) using ferricyanide as redox mediator. The biosensor was able to discriminate two different oxidation states of chromium being able to reject Cr(III) and to detect the toxic species Cr(VI). Chronoamperometric response of the biosensor towards glucose decreases with the presence of Cr(VI), with a capability of detection of 90.5±7.6 nM and a reproducibility of 6.2%. A bipotentiostatic chronoamperometric biosensor was finally developed using a tyrosinase/SPC(TTF)E and a GOx/SPC(Pt)E connected in array mode for the simultaneous determination of Cr(III) and Cr(VI) in spiked tap water and in waste water from a tannery factory samples.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biosensor; Chromium speciation; Enzymatic inhibition; Glucose oxidase; Screen-printed electrodes; Tyrosinase

Mesh:

Substances:

Year:  2014        PMID: 24909769     DOI: 10.1016/j.aca.2014.05.006

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Gold nanostar-based voltammetric sensor for chromium(VI).

Authors:  Susom Dutta; Guinevere Strack; Pradeep Kurup
Journal:  Mikrochim Acta       Date:  2019-10-31       Impact factor: 5.833

2.  Development of glucose oxidase-chitosan immobilized paper biosensor using screen-printed electrode for amperometric detection of Cr(VI) in water.

Authors:  Ajinkya Dabhade; Sivaraman Jayaraman; Balasubramanian Paramasivan
Journal:  3 Biotech       Date:  2021-03-22       Impact factor: 2.406

3.  Utility of Ochrobactrum anthropi YC152 in a Microbial Fuel Cell as an Early Warning Device for Hexavalent Chromium Determination.

Authors:  Guey-Horng Wang; Chiu-Yu Cheng; Man-Hai Liu; Tzu-Yu Chen; Min-Chi Hsieh; Ying-Chien Chung
Journal:  Sensors (Basel)       Date:  2016-08-16       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.