Literature DB >> 24908356

Evaluation of a CT-based technique to measure the transfer accuracy of a virtually planned osteotomy.

J G G Dobbe1, A J Kievit2, M U Schafroth2, L Blankevoort2, G J Streekstra3.   

Abstract

Accurate transfer of a preoperatively planned osteotomy plane to the bone is of significance for corrective surgery, tumor resection, implant positioning and evaluation of new osteotomy techniques. Methods for comparing a preoperatively planned osteotomy plane with a surgical cut exist but the accuracy of these techniques are either limited or unknown. This paper proposes and evaluates a CT-based technique that enables comparing virtual with actual osteotomy planes. The methodological accuracy and reproducibility of the technique is evaluated using CT-derived volume data of a cadaver limb, which serves to plan TKA osteotomies in 3-D space and to simulate perfect osteotomies not hampered by surgical errors. The methodological variability of the technique is further investigated with repeated CT scans after actual osteotomy surgery of the same cadaver specimen. Plane displacement (derr) and angulation errors in the sagittal and coronal plane (βerr, γerr) are measured with high accuracy and reproducibility (derr=-0.11±0.06mm; βerr=0.08±0.04°, γerr=-0.03±0.03°). The proposed method for evaluating an osteotomy plane position and orientation has a high intrinsic accuracy and reproducibility. The method can be of great value for measuring the transfer accuracy of new techniques for positioning and orienting a surgical cut in 3-D space.
Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Corrective osteotomy; Cutting guide; Patient specific instrumentation; TKA; Virtual planning

Mesh:

Year:  2014        PMID: 24908356     DOI: 10.1016/j.medengphy.2014.05.012

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  4 in total

1.  Rapid Prototyping 3D Model in Treatment of Pediatric Hip Dysplasia: A Case Report.

Authors:  Andrew M Holt; Zbigniew Starosolski; J Herman Kan; Scott B Rosenfeld
Journal:  Iowa Orthop J       Date:  2017

2.  Predicted osteotomy planes are accurate when using patient-specific instrumentation for total knee arthroplasty in cadavers: a descriptive analysis.

Authors:  A J Kievit; J G G Dobbe; G J Streekstra; L Blankevoort; M U Schafroth
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-09-25       Impact factor: 4.342

3.  A 3D printed cast for minimally invasive transfer of distal radius osteotomy: a cadaver study.

Authors:  G Caiti; J G G Dobbe; S D Strackee; M H M van Doesburg; G J Strijkers; G J Streekstra
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-01-21       Impact factor: 2.924

4.  Lower leg symmetry: a Q3D-CT analysis.

Authors:  Gwendolyn Vuurberg; Jari Dahmen; Iwan G G Dobbe; Roeland P Kleipool; Batur Hayat; Inger N Sierevelt; Geert Streekstra; Gino M M J Kerkhoffs; Sjoerd A S Stufkens
Journal:  Surg Radiol Anat       Date:  2022-05-10       Impact factor: 1.354

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.