Occlusion of canine aneurysms using microporous self-expanding stent grafts: long-term follow-up.

Shogo Nishi1, Yasuhide Nakayama2, Hatsue Ishibashi-Ueda3, Yoshida Masato4.   

Abstract

PURPOSE: The treatment of large or giant cerebral aneurysms by surgical and/or endovascular techniques is difficult and poses relatively high risks. Therefore, a microporous self-expanding (hybrid) stent graft composed of a thin, expandable, segmented polyurethane (SPU) membrane with micropores and a drug-delivery system was developed.
MATERIALS AND METHODS: A commercially available, self-expanding carotid stent was covered with a thin microporous SPU membrane fabricated by the dip-coating method and the excimer laser ablation technique, with an intraluminal coating of argatroban. Experimentally fabricated lateral-wall aneurysms in canine carotid arteries using venous pouches were occluded with the hybrid stent graft (bale-shaped pore density of 23.6%) on one side and a bare-metal stent on the other side without systemic antiplatelet therapy.
RESULTS: Angiography at 1, 6, and 12 months of stenting revealed that all arteries were patent without marked stenosis without systemic antiplatelet therapy. All aneurysms treated with hybrid stent grafts remained occluded throughout the 12-month period, while among those treated by bare-metal stents, 2 of 3 aneurysms were occluded at 6 months (67%) and only 1 of 3 aneurysms were occluded at 12 months (33%). Histology revealed that the novel hybrid stent graft had less intimal hyperplasia than the bare-metal stent. The hybrid stent graft was useful for the successful occlusion of these canine carotid aneurysms, even at 12 months.
CONCLUSIONS: The novel hybrid stent grafts are expected to overcome the disadvantages of fully covered stent grafts and simple bare-metal stents, while combining both their merits, and appear to be useful in the treatment of large or giant cerebral aneurysms.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Canine experimental aneurysms; Covered stents; Hybrid stent grafts; Long-term follow-up; Microporous self-expanding stent graft

Mesh:

Year:  2014        PMID: 24908214     DOI: 10.1016/j.clineuro.2014.04.013

Source DB:  PubMed          Journal:  Clin Neurol Neurosurg        ISSN: 0303-8467            Impact factor:   1.876


  3 in total

1.  Construction of 3 animal experimental models in the development of honeycomb microporous covered stents for the treatment of large wide-necked cerebral aneurysms.

Authors:  Yasuhide Nakayama; Tetsu Satow; Marina Funayama; Takeshi Moriwaki; Tsutomu Tajikawa; Maya Furukoshi; Eika Hamano; Daizo Ishi; Masataka Hayashi; Sei Sugata; Hatsue Ishibashi-Ueda; Jun C Takahashi
Journal:  J Artif Organs       Date:  2016-01-07       Impact factor: 1.731

2.  Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm.

Authors:  Siang Lin Yeow; Hwa Liang Leo
Journal:  Comput Math Methods Med       Date:  2016-05-09       Impact factor: 2.238

Review 3.  Modification strategies to improve the membrane hemocompatibility in extracorporeal membrane oxygenator (ECMO).

Authors:  Ting He; Jinhui He; Zhaohui Wang; Zhaoliang Cui
Journal:  Adv Compos Hybrid Mater       Date:  2021-05-03
  3 in total