Pacemakers and implantable cardioverter defibrillators--general and anesthetic considerations.

Amy G Rapsang1, Prithwis Bhattacharyya2.   

Abstract

A pacemaking system consists of an impulse generator and lead or leads to carry the electrical impulse to the patient's heart. Pacemaker and implantable cardioverter defibrillator codes were made to describe the type of pacemaker or implantable cardioverter defibrillator implanted. Indications for pacing and implantable cardioverter defibrillator implantation were given by the American College of Cardiologists. Certain pacemakers have magnet-operated reed switches incorporated; however, magnet application can have serious adverse effects; hence, devices should be considered programmable unless known otherwise. When a device patient undergoes any procedure (with or without anesthesia), special precautions have to be observed including a focused history/physical examination, interrogation of pacemaker before and after the procedure, emergency drugs/temporary pacing and defibrillation, reprogramming of pacemaker and disabling certain pacemaker functions if required, monitoring of electrolyte and metabolic disturbance and avoiding certain drugs and equipments that can interfere with pacemaker function. If unanticipated device interactions are found, consider discontinuation of the procedure until the source of interference can be eliminated or managed and all corrective measures should be taken to ensure proper pacemaker function should be done. Post procedure, the cardiac rate and rhythm should be monitored continuously and emergency drugs and equipments should be kept ready and consultation with a cardiologist or a pacemaker-implantable cardioverter defibrillator service may be necessary.
Copyright © 2013 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

Entities:  

Keywords:  Anesthesia for device patients; Implantable cardioverter defibrillators; Pacemakers

Mesh:

Substances:

Year:  2013        PMID: 24907883     DOI: 10.1016/j.bjane.2013.02.005

Source DB:  PubMed          Journal:  Braz J Anesthesiol


  2 in total

1.  Anaesthetic challenges in a child with sickle-cell disease and congenital heart block.

Authors:  Indu Bala; Neeru Sahni; Sanwar Mal Mitharwal
Journal:  Indian J Anaesth       Date:  2016-04

2.  An uncommon intraoperative implantable cardiac device complication and subsequent troubleshooting.

Authors:  Rekha Suthar; Omar Viswanath; S Howard Wittels; Gerald P Rosen
Journal:  Ann Card Anaesth       Date:  2017 Oct-Dec
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.