Satoko Kimura1, Tomonari Akamatsu2, Lijun Dong3, Kexiong Wang3, Ding Wang3, Yasutoki Shibata4, Nobuaki Arai5.
Abstract
Passive acoustic monitoring for cetaceans mainly employ fixed-location methods or point transect samplings; an acoustic survey from a moving platform to conduct line transects is less common. In this study, acoustic capture-recapture by combining a double-observer method with line transect sampling was performed to observe Yangtze finless porpoises. Two acoustic devices were towed with the distance between them varying 0.5 to 89.5 m. The conditional probabilities that both devices would detect the porpoises within the same time window were calculated. In a 1-s time window, it became smaller as the distance between the devices increased, approaching zero when the distance between them was more than 50 m. It was considered that the devices with less than 50 m distance detected the same signals from the same animals, which means the identical detection. When the distance between them is too great, the recapture rate is reduced and the incidence of false matching may increase. Thus, a separation distance of around 50 m between two devices in acoustic capture-recapture of Yangtze finless porpoises was recommended. Note that the performance of the double detections can change depending on the particular device used and on animal behaviors such as vocalizing interval, ship avoidance.Entities:
Mesh:
Substances:
Year: 2014 PMID: 24907799 DOI: 10.1121/1.4875710
Source DB: PubMed Journal: J Acoust Soc Am ISSN: 0001-4966 Impact factor: 1.840