Literature DB >> 24907753

Electroanalytical studies on Cu (II) ion-selective sensor of coated pyrolytic graphite electrodes based on N2S2O2 and N2S2O3 heterocyclic benzothiazol ligands.

A K Singh1, Manoj Kumar Sahani2, Koteswara Rao Bandi2, A K Jain2.   

Abstract

Benzothiazol based chelating ionophores such as 1,3-bis[2-(1,3-benzothiazol-2-yl)-phenoxy]propane (L1) and 1,2'-bis[2-(1,3-benzothiazol-2-yl)-phenoxy]2-ethoxyethane(L2) were synthesized and explored as neutral ionophores in the fabrication of Cu(2+) ion-selective electrodes. Variety of PVC-based electrodes i.e., polymeric membrane electrodes (PME), coated graphite electrodes (CGE) and coated pyrolytic graphite electrodes (CPGE) were prepared. The membranes having composition L1:PVC:1-CN:NaTPB≡5:38:55:2 (w/w; mg) and L2:PVC:1-CN:NaTPB in the ratio of 6:39:53:2 are found to be exhibit the best potentiometric characteristics. The comparative studies of PME, CGE and CPGE based on L2 reveals that the CPGE is superior in terms of low detection limit of 6.30×10(-9) mol L(-1) with a Nernstian slope of 29.5 mV decade(-1) of activity between pH2.0 to 8.5 with a fast response time of 9s and could be used over a period of 5 months without any significant divergence in its potentiometric characteristics. The sensor has been employed for the estimation of Cu(2+) ion in real samples viz., water, soil and herbal medicinal plants and besides this, the sensor was also used as an indicator electrode in the potentiometric determination of Cu(2+) with EDTA.
Copyright © 2014. Published by Elsevier B.V.

Entities:  

Keywords:  Coated pyrolytic graphite electrode; Cu(2+) ion-selective electrode; Heterocyclic benzothiazol ligands; Polymeric membrane electrode; Potentiometry

Mesh:

Substances:

Year:  2014        PMID: 24907753     DOI: 10.1016/j.msec.2014.04.047

Source DB:  PubMed          Journal:  Mater Sci Eng C Mater Biol Appl        ISSN: 0928-4931            Impact factor:   7.328


  2 in total

1.  Dynamic potential and surface morphology study of sertraline membrane sensors.

Authors:  M M Khater; Y M Issa; H B Hassib; S H Mohammed
Journal:  J Adv Res       Date:  2014-12-01       Impact factor: 10.479

2.  Determination of total mercury in seafood by ion-selective electrodes based on a thiol functionalized ionic liquid.

Authors:  Juan Miao; Xin Wang; Yunchang Fan; Jing Li; Lina Zhang; Guitao Hu; Can He; Can Jin
Journal:  J Food Drug Anal       Date:  2017-09-22       Impact factor: 6.157

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.