Literature DB >> 24907140

Coxofemoral joint kinematics using video fluoroscopic images of treadmill-walking cats: development of a technique to assess osteoarthritis-associated disability.

Martin Guillot1, Pierre Gravel2, Marie-Lou Gauthier3, Hugues Leblond4, Maurice Tremblay4, Serge Rossignol4, Johanne Martel-Pelletier5, Jean-Pierre Pelletier5, Jacques A de Guise6, Eric Troncy7.   

Abstract

The objectives of this pilot study were to develop a video fluoroscopy kinematics method for the assessment of the coxofemoral joint in cats with and without osteoarthritis (OA)-associated disability. Two non-OA cats and four cats affected by coxofemoral OA were evaluated by video fluoroscopy. Video fluoroscopic images of the coxofemoral joints were captured at 120 frames/s using a customized C-arm X-ray system while cats walked freely on a treadmill at 0.4 m/s. The angle patterns over time of the coxofemoral joints were extracted using a graphic user interface following four steps: (i) correction for image distortion; (ii) image denoising and contrast enhancement; (iii) frame-to-frame anatomical marker identification; and (iv) statistical gait analysis. Reliability analysis was performed. The cats with OA presented greater intra-subject stride and gait cycle variability. Three cats with OA presented a left-right asymmetry in the range of movement of the coxofemoral joint angle in the sagittal plane (two with no overlap of the 95% confidence interval, and one with only a slight overlap) consistent with their painful OA joint, and a longer gait cycle duration. Reliability analysis revealed an absolute variation in the coxofemoral joint angle of 2º-6º, indicating that the two-dimensional video fluoroscopy technique provided reliable data. Improvement of this method is recommended: variability would likely be reduced if a larger field of view could be recorded, allowing the identification and tracking of each femoral axis, rather than the trochanter landmarks. The range of movement of the coxofemoral joint has the potential to be an objective marker of OA-associated disability. © ISFM and AAFP 2014.

Entities:  

Mesh:

Year:  2014        PMID: 24907140     DOI: 10.1177/1098612X14537261

Source DB:  PubMed          Journal:  J Feline Med Surg        ISSN: 1098-612X            Impact factor:   2.015


  1 in total

1.  Preliminary Validation and Reliability Testing of the Montreal Instrument for Cat Arthritis Testing, for Use by Veterinarians, in a Colony of Laboratory Cats.

Authors:  Mary P Klinck; Pascale Rialland; Martin Guillot; Maxim Moreau; Diane Frank; Eric Troncy
Journal:  Animals (Basel)       Date:  2015-12-02       Impact factor: 2.752

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.