Literature DB >> 24905878

Effects of biomechanical properties of the bone-implant interface on dental implant stability: from in silico approaches to the patient's mouth.

Guillaume Haïat1, Hom-Lay Wang, John Brunski.   

Abstract

Dental implants have become a routinely used technique in dentistry for replacing teeth. However, risks of failure are still experienced and remain difficult to anticipate. Multiscale phenomena occurring around the implant interface determine the implant outcome. The aim of this review is to provide an understanding of the biomechanical behavior of the interface between a dental implant and the region of bone adjacent to it (the bone-implant interface) as a function of the interface's environment. First, we describe the determinants of implant stability in relation to the different multiscale simulation approaches used to model the evolution of the bone-implant interface. Then, we review the various aspects of osseointegration in relation to implant stability. Next, we describe the different approaches used in the literature to measure implant stability in vitro and in vivo. Last, we review various factors affecting the evolution of the bone-implant interface properties.

Entities:  

Keywords:  biomechanical properties; bone; bone remodeling; bone–implant interface; dental implant; osseointegration; stability

Mesh:

Substances:

Year:  2014        PMID: 24905878     DOI: 10.1146/annurev-bioeng-071813-104854

Source DB:  PubMed          Journal:  Annu Rev Biomed Eng        ISSN: 1523-9829            Impact factor:   9.590


  15 in total

1.  Evaluation of accuracy in implant site preparation performed in single- or multi-step drilling procedures.

Authors:  Nadine Marheineke; Uta Scherer; Martin Rücker; Constantin von See; Björn Rahlf; Nils-Claudius Gellrich; Marcus Stoetzer
Journal:  Clin Oral Investig       Date:  2017-12-17       Impact factor: 3.573

2.  Ultrasonic Evaluation of the Bone-Implant Interface.

Authors:  Yoann Hériveaux; Vu-Hieu Nguyen; Guillaume Haïat
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 2.622

3.  Mechanical micromodeling of stress-shielding at the bone-implant interphase under shear loading.

Authors:  Yoann Hériveaux; Sophie Le Cann; Manon Fraulob; Elsa Vennat; Vu-Hieu Nguyen; Guillaume Haïat
Journal:  Med Biol Eng Comput       Date:  2022-09-28       Impact factor: 3.079

4.  Micromechanical modeling of the contact stiffness of an osseointegrated bone-implant interface.

Authors:  Maria Letizia Raffa; Vu-Hieu Nguyen; Guillaume Haiat
Journal:  Biomed Eng Online       Date:  2019-12-03       Impact factor: 2.819

5.  Evaluation of the effects of topically applied simvastatin on titanium implant osseointegration.

Authors:  Serkan Dundar; Alihan Bozoglan
Journal:  J Oral Biol Craniofac Res       Date:  2020-04-17

6.  Assessing the Acetabular Cup Implant Primary Stability by Impact Analyses: A Cadaveric Study.

Authors:  Adrien Michel; Romain Bosc; Jean-Paul Meningaud; Philippe Hernigou; Guillaume Haiat
Journal:  PLoS One       Date:  2016-11-28       Impact factor: 3.240

7.  Osteogenic activity of titanium surfaces with hierarchical micro-/nano-structures obtained by hydrofluoric acid treatment.

Authors:  Jianfei Liang; Shanshan Xu; Mingming Shen; Bingkun Cheng; Yongfeng Li; Xiangwei Liu; Dongze Qin; Anuj Bellare; Liang Kong
Journal:  Int J Nanomedicine       Date:  2017-02-16

8.  Monitoring the Changes of Material Properties at Bone-Implant Interface during the Healing Process In Vivo: A Viscoelastic Investigation.

Authors:  Hsiang-Ho Chen; Wei-Yi Lai; Tze-Jian Chee; Ya-Hui Chan; Sheng-Wei Feng
Journal:  Biomed Res Int       Date:  2017-03-08       Impact factor: 3.411

9.  Micro/Nano Structural Tantalum Coating for Enhanced Osteogenic Differentiation of Human Bone Marrow Stem Cells.

Authors:  Ding Ding; Youtao Xie; Kai Li; Liping Huang; Xuebin Zheng
Journal:  Materials (Basel)       Date:  2018-04-03       Impact factor: 3.623

10.  Comparison of Resonance Frequency Analysis and of Quantitative Ultrasound to Assess Dental Implant Osseointegration.

Authors:  Romain Vayron; Vu-Hieu Nguyen; Benoît Lecuelle; Hugues Albini Lomami; Jean-Paul Meningaud; Romain Bosc; Guillaume Haiat
Journal:  Sensors (Basel)       Date:  2018-05-02       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.