Literature DB >> 24901067

Contemporary esthetic nickel-titanium wires: do they deliver the same forces?

Bradford Washington1, Carla A Evans, Grace Viana, Ana Bedran-Russo, Spiro Megremis.   

Abstract

OBJECTIVE: To test for differences in loading and unloading forces delivered by six coated nickel-titanium wires and their noncoated equivalents.
MATERIALS AND METHODS: From six commercial companies, 0.016-inch diameter round and 0.016 × 0.022-inch rectangular cross-section nickel-titanium wires were procured "as is": Rocky Mountain Orthodontics (Denver, Colo), TP Orthodontics (La Porte, Ind), American Orthodontics (AO; Sheboygan, Wis), G&H (Franklin, Ind), Opal Orthodontics (South Jordan, Utah), and Forestadent USA (St Louis, Mo) (round only). The wires were evaluated using a three-point bending test based on the method in ISO Standard 15841.
RESULTS: No statistically significant differences (P > .05) in force values were found between coated and noncoated wires, listed by deflection in three-point bending, for these specific groups: 1 mm, TP round; 2 mm, TP round and G&H rectangular; 3 mm, G&H round and G&H rectangular; 2.5 mm,TP round and G&H rectangular; 1.5 mm, TP round, G&H round, G&H rectangular, and AO rectangular; and 0.5 mm, AO rectangular and G&H round.
CONCLUSION: Some manufacturers market esthetic wires delivering forces similar to the equivalent noncoated wires, when tested according to a standard three-point bend method.

Entities:  

Keywords:  Nickel-titanium archwires; Orthodontics

Mesh:

Substances:

Year:  2015        PMID: 24901067     DOI: 10.2319/092513-701.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  4 in total

1.  Evaluation of the Loading, Unloading, and Permanent Deformation of Newly Available Epoxy Resin Coated Ni-Ti Wires Using Self-Ligating Brackets.

Authors:  Hazel Garro-Piña; María Cristina Jiménez-Cervantes; Ricardo Ondarza-Rovira; Roberto Justus; Salvador García-López
Journal:  Int J Dent       Date:  2017-05-23

2.  Evaluation of Nanomechanical Properties, Surface Roughness, and Color Stability of Esthetic Nickel-Titanium Orthodontic Archwires.

Authors:  Jamal A Alsanea; Hassan Al Shehri
Journal:  J Int Soc Prev Community Dent       Date:  2019-02-14

3.  Evaluating the Mechanical Properties of Zinc-Coated Stainless Steel Orthodontic Wires Using Physical Vapor Deposition.

Authors:  Maryam Karandish; Mahmoud Pakshir; Milad Moghimi; Dana Jafarpour
Journal:  Int J Dent       Date:  2021-05-03

4.  Comparison of deflection forces of esthetic archwires combined with ceramic brackets.

Authors:  Murilo Matias; Marcos Roberto de Freitas; Karina Maria Salvatore de Freitas; Guilherme Janson; Rodrigo Hitoshi Higa; Manoela Fávaro Francisconi
Journal:  J Appl Oral Sci       Date:  2018-02-08       Impact factor: 2.698