Literature DB >> 24899253

Degradation of poly-D-L-lactide (PDLLA) interference screws (Megafix ®).

Andrea Achtnich1, Philipp Forkel, Sebastain Metzlaff, Thore Zantop, Wolf Petersen.   

Abstract

INTRODUCTION: Interference screw fixation is a standard procedure in anterior cruciate ligament (ACL) replacement. Aim of this study was to evaluate the degradation process of Poly-D-L-lactide (PDLLA) interference screws used for tibial ACL graft fixation.
MATERIALS AND METHODS: We evaluated magnetic resonance imaging (MRI) scans of 18 patients who underwent ACL revision surgery at different time points after anatomic ACL reconstruction. At primary surgery, a tibial hybrid fixation was performed with a degradable interference (IF) screw made of PDLLA (Megafix(®)) and a button.
RESULTS: MRI revealed three different phases of degradation of the PDLLA screw. 6-8 months after surgery the IF screw was clearly visible as a well-defined structure on MRI and CT scan. After 12-16 months, the screws appeared less defined with central ingrowths' of connective tissue. In some cases only fragmented screw material was visible. At these time points, there was a slight edema surrounding the tunnel visible on MRI. After 22 months and later, the mean screw site densities were comparable with the surrounding bone density. There was no edema or signs of inflammation around the bone tunnels visible. Presence of cystic or osteolytic changes was not detected.
CONCLUSION: After 22 months, a PDLLA screw may not interfere with ACL revision surgery. Regarding the degradation process of PDLLA screws, we noted three different phases. Furthermore, the degradation process observed by MRI resembles to that described by animal studies. The PDLLA screws fully absorb and are partially replaced by bone. The degradation process in humans seems to be longer than that described in animals.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24899253     DOI: 10.1007/s00402-014-2013-9

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  4 in total

Review 1.  Magnetic resonance imaging after anterior cruciate ligament reconstruction: A practical guide.

Authors:  Alberto Grassi; James R Bailey; Cecilia Signorelli; Giuseppe Carbone; Andy Tchonang Wakam; Gian Andrea Lucidi; Stefano Zaffagnini
Journal:  World J Orthop       Date:  2016-10-18

2.  Guided bone regeneration using a bone tissue engineering complex consisting of a poly-dl-lactide membrane and bone mesenchymal stem cells.

Authors:  Dahui Wang; Yifeng Lin; Lian Chen; Yueqiang Mo; Peng Huang; Ruixue Ma
Journal:  Oncotarget       Date:  2017-12-22

3.  Bone ingrowth into open architecture PEEK interference screw after ACL reconstruction.

Authors:  Martin Lind; Torsten Nielsen; Ole Gade Sørensen; Bjarne Mygind-Klavsen; Peter Faunø; Stacy Leake-Gardner
Journal:  J Exp Orthop       Date:  2020-09-18

4.  Evaluation of the degradation of two bioabsorbable interference screws: an in-vivo study in sheep.

Authors:  Paulo Sérgio Scorsato; Sheila Canevese Rahal; Tania Mary Cestari; Maria Jaqueline Mamprim; Danuta Pulz Doiche; Daniel de Bortoli Teixeira; Rafael Cerântola Siqueira; Marcílio Felix
Journal:  Acta Cir Bras       Date:  2022-06-27       Impact factor: 1.564

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.