Proposal of renal artery's ostial projection under virtual geometric correction in infrarenal aneurysms: initial results of a pilot study.

Giovani José Dal Poggetto Molinari, Andreia Marques de Oliveira Dalbem, Fabio Hüsemann Menezes, Ana Terezinha Guillaumon.   

Abstract

INTRODUCTION: Endovascular aneurysm repair requires the precise deployment of the graft. In order to achieve accurate positioning, the anatomical and morphological characteristics of the aorta and its branches is mandatory. Software that perform three dimensional reformatting of multislice tomographic images, allow for the study of the whole aorto-iliac axis and the perpendicular visualization of the origin of the renal arteries. The correct length of the proximal neck can be evaluated and adequate graft fixation and sealing may be foreseen. A technique is presented, using an software, for the orthogonal correction of the position of the renal arteries in relation to the proximal neck, which may guide the radioscopic orientation intraoperatively.
METHODS: Within a multiplanar tomographic image reconstruction, virtual triangulation allows for the three dimensional orthogonal correction of the renal arteries' ostia position. The predetermined best angulations for visualization are annotated and used for the positioning of the surgical C-arm. RESULTS/DISCUSSION: Some authors discuss that the anatomic position of the renal vessels seen on the tomographic scan can change during the surgical procedure. It is known that the renal arterys' angular positioning does not alter, even after insertion of stiff guidewires, introducers, and the endograft itself. Therefore, it is possible, using concepts of spacial geometry and orthogonal correction, to predict the ideal bidimensional intraoperative positioning of the radioscopy device in order to reproduce the optimized renal artery ostial projection, ensuring the best accuracy during endograft deployment.
CONCLUSION: As closer to the tomographic reproduction was the radioscopic correction, more careful is the visualization of the ostium of the renal artery, better is the exploitation of the lap for fixing and sealing and the endoprosthesis deployment is more accurate.

Entities:  

Mesh:

Year:  2014        PMID: 24896166      PMCID: PMC4389474          DOI: 10.5935/1678-9741.20140014

Source DB:  PubMed          Journal:  Rev Bras Cir Cardiovasc


  3 in total

1.  Two-dimensional versus three-dimensional CT angiography in analysis of anatomical suitability for stentgraft repair of abdominal aortic aneurysms.

Authors:  Georgios A Pitoulias; Konstantinos P Donas; Stefan Schulte; Eleni A Aslanidou; Dimitrios K Papadimitriou
Journal:  Acta Radiol       Date:  2011-04-01       Impact factor: 1.990

2.  Tips and techniques for optimal stent graft placement in angulated aneurysm necks.

Authors:  Jasper W van Keulen; Frans L Moll; Joost A van Herwaarden
Journal:  J Vasc Surg       Date:  2010-05-15       Impact factor: 4.268

3.  Validation of a new standardized method to measure proximal aneurysm neck angulation.

Authors:  Jasper W van Keulen; Frans L Moll; Jip L Tolenaar; Hence J M Verhagen; Joost A van Herwaarden
Journal:  J Vasc Surg       Date:  2010-04       Impact factor: 4.268

  3 in total
  5 in total

1.  Efficacy Analysis of a Script-based Guide for EVAR Execution: is it Possible to Reduce Patient Exposure to Contrast, Operative Time and Blood Loss even when Advanced Technologies are not Available?

Authors:  Giovani José Dal Poggetto Molinari; Ana Terezinha Guillaumon; Andréia Marques de Oliveira Dalbem
Journal:  Braz J Cardiovasc Surg       Date:  2015 Nov-Dec

2.  Avoiding pitfalls of intraoperative peripheral endovascular surgery with the aid of OsiriX: expanding the use of virtual fluoroscopy.

Authors:  Giovani José Dal Poggetto Molinari; Andréia Marques de Oliveira Dalbem; Ana Terezinha Guillaumon
Journal:  Rev Bras Cir Cardiovasc       Date:  2014 Jul-Sep

3.  Three-dimensional semi-automated volumetric assessment of the pulp space of teeth following regenerative dental procedures.

Authors:  Heeresh Shetty; Shishir Shetty; Adesh Kakade; Aditya Shetty; Mohmed Isaqali Karobari; Ajinkya M Pawar; Anand Marya; Artak Heboyan; Adith Venugopal; The Hanh Nguyen; Dinesh Rokaya
Journal:  Sci Rep       Date:  2021-11-09       Impact factor: 4.379

4.  New infusion device for use in acquisition of images during endovascular procedures: an experimental model.

Authors:  Bruno Pagnin Schmid; Isadora Cardoso de Alencar; Carolina Masson; Giovani José Dal Poggetto Molinari; Fábio Hüsemann Menezes
Journal:  J Vasc Bras       Date:  2021-06-11

5.  Comments on "Innovation and excellence: changing to prevail the Brazilian cardiovascular surgery".

Authors:  Sergio Francisco dos Santos Junior
Journal:  Rev Bras Cir Cardiovasc       Date:  2014 Jan-Mar