Literature DB >> 24893271

Comparison of two automated solid phase extractions for the detection of ten fentanyl analogs and metabolites in human urine using liquid chromatography tandem mass spectrometry.

Rebecca L Shaner1, Pearl Kaplan2, Elizabeth I Hamelin1, William A Bragg1, Rudolph C Johnson3.   

Abstract

Two types of automated solid phase extraction (SPE) were assessed for the determination of human exposure to fentanyls in urine. High sensitivity is required to detect these compounds following exposure because of the low dose required for therapeutic effect and the rapid clearance from the body for these compounds. To achieve this sensitivity, two acceptable methods for the detection of human exposure to seven fentanyl analogs and three metabolites were developed using either off-line 96-well plate SPE or on-line SPE. Each system offers different advantages: off-line 96-well plate SPE allows for high throughput analysis of many samples, which is needed for large sample numbers, while on-line SPE removes almost all analyst manipulation of the samples, minimizing the analyst time needed for sample preparation. Both sample preparations were coupled with reversed phase liquid chromatography and isotope dilution tandem mass spectrometry (LC-MS/MS) for analyte detection. For both methods, the resulting precision was within 15%, the accuracy within 25%, and the sensitivity was comparable with the limits of detection ranging from 0.002ng/mL to 0.041ng/mL. Additionally, matrix effects were substantially decreased from previous reports for both extraction protocols. The results of this comparison showed that both methods were acceptable for the detection of exposures to fentanyl analogs and metabolites in urine. Published by Elsevier B.V.

Entities:  

Keywords:  Automation; Fentanyl; Fentanyls; Liquid chromatography; Mass spectrometry; Method development; Solid phase extraction

Mesh:

Substances:

Year:  2014        PMID: 24893271      PMCID: PMC4812561          DOI: 10.1016/j.jchromb.2014.05.025

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  26 in total

1.  Development and validation of a highly sensitive gas chromatographic-mass spectrometric screening method for the simultaneous determination of nanogram levels of fentanyl, sufentanil and alfentanil in air and surface contamination wipes.

Authors:  Nadine F J Van Nimmen; Hendrik A F Veulemans
Journal:  J Chromatogr A       Date:  2004-05-07       Impact factor: 4.759

2.  A new automated urine fentanyl immunoassay: technical performance and clinical utility for monitoring fentanyl compliance.

Authors:  Marion L Snyder; Petr Jarolim; Stacy E F Melanson
Journal:  Clin Chim Acta       Date:  2011-01-31       Impact factor: 3.786

3.  Analysis of 13 fentanils, including sufentanil and carfentanil, in human urine by liquid chromatography-atmospheric-pressure ionization-tandem mass spectrometry.

Authors:  Lanqing Wang; John T Bernert
Journal:  J Anal Toxicol       Date:  2006-06       Impact factor: 3.367

4.  The bogus drug: Three methyl & alpha methyl fentanyl sold as "China White".

Authors:  W A Ayres; M J Starsiak; P Sokolay
Journal:  J Psychoactive Drugs       Date:  1981 Jan-Mar

5.  Determination of fentanyl in human plasma and fentanyl and norfentanyl in human urine using LC-MS/MS.

Authors:  N-H Huynh; N Tyrefors; L Ekman; M Johansson
Journal:  J Pharm Biomed Anal       Date:  2005-04-29       Impact factor: 3.935

6.  A comprehensive LC-MS-based quantitative analysis of fentanyl-like drugs in plasma and urine.

Authors:  Sarah Cooreman; Christa Deprez; Frank Martens; Jan Van Bocxlaer; Kathleen Croes
Journal:  J Sep Sci       Date:  2010-09       Impact factor: 3.645

7.  Simultaneous quantification of davalintide, a novel amylin-mimetic peptide, and its active metabolite in beagle and rat plasma by online SPE and LC-MS/MS.

Authors:  Yan Wang; Ying Qu; Chris L Bellows; John S Ahn; Jennifer L Burkey; Steven W Taylor
Journal:  Bioanalysis       Date:  2012-09       Impact factor: 2.681

8.  The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compounds.

Authors: 
Journal:  Rapid Commun Mass Spectrom       Date:  1999-06       Impact factor: 2.419

9.  Development of a homogeneous immunoassay for the detection of fentanyl in urine.

Authors:  Guohong Wang; Kim Huynh; Rekha Barhate; Warren Rodrigues; Christine Moore; Cynthia Coulter; Michael Vincent; James Soares
Journal:  Forensic Sci Int       Date:  2011-03-20       Impact factor: 2.395

10.  An outbreak of designer drug--related deaths in Pennsylvania.

Authors:  J Hibbs; J Perper; C L Winek
Journal:  JAMA       Date:  1991-02-27       Impact factor: 56.272

View more
  3 in total

1.  Quantitation of Fentanyl Analogs in Dried Blood Spots by Flow-Through Desorption Coupled to Online Solid Phase Extraction Tandem Mass Spectrometry.

Authors:  Rebecca L Shaner; Nicholas D Schulze; Craig Seymour; Elizabeth I Hamelin; Jerry D Thomas; Rudolph C Johnson
Journal:  Anal Methods       Date:  2017-06-16       Impact factor: 2.896

2.  Development and validation of a high-throughput online solid phase extraction - Liquid chromatography - Tandem mass spectrometry method for the detection of tetrodotoxin in human urine.

Authors:  Rebecca Coleman; Sharon W Lemire; William Bragg; Alaine Garrett; Geovannie Ojeda-Torres; Elizabeth Hamelin; Rudolph C Johnson; Jerry Thomas
Journal:  Toxicon       Date:  2016-05-19       Impact factor: 3.033

3.  LC-MS/MS-Based Method for the Multiplex Detection of 24 Fentanyl Analogues and Metabolites in Whole Blood at Sub ng mL-1 Concentrations.

Authors:  Kraig E Strayer; Heather M Antonides; Matthew P Juhascik; Raminta Daniulaityte; Ioana E Sizemore
Journal:  ACS Omega       Date:  2018-01-17
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.