Literature DB >> 24890940

Six-year clinical outcome of single implant-retained mandibular overdentures--a pilot study.

Nicole Passia1, Stefan Wolfart2, Matthias Kern1.   

Abstract

OBJECTIVES: The aim of this prospective pilot study was to evaluate the prosthodontic maintenance as well as the implant outcome of single implant-retained mandibular overdentures over an observation period of 6 years.
METHODS: Eleven edentulous patients received one single implant in the midline of the mandible. Denture bases were temporarily relined and 2 months later provided with a ball attachment for implant retention. Implant related parameters and prosthodontic maintenance interventions were assessed 4 weeks after implant loading and then once a year.
RESULTS: Over a mean observation period of 75.9 months, no implant was lost. The most frequent prosthetic maintenance intervention was activation of the matrix due to loss of retention, followed by exchange of the female part. Eight denture bases had to be repaired after a fracture in the midline area.
CONCLUSIONS: Within the limitations of this preliminary clinical study, the concept of a single midline implant to retain a mandibular complete denture was a successful treatment option for elderly edentulous patients.
© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  edentulous mandible; implant therapy; implant-supported overdenture; mandibular complete denture; single midline implant

Mesh:

Year:  2014        PMID: 24890940     DOI: 10.1111/clr.12427

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  8 in total

1.  Comparison of marginal bone loss and patient satisfaction in single and double-implant assisted mandibular overdenture by immediate loading.

Authors:  Sara Tavakolizadeh; Fariborz Vafaee; Masume Khoshhal; Zahra Ebrahimzadeh
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

2.  Pain and discomfort following immediate and delayed loading by overdentures in the single mandibular implant study (SMIS).

Authors:  T Mundt; N Passia; W Att; G Heydecke; S Freitag-Wolf; R G Luthardt; S Kappel; I K Konstantinidis; M Stiesch; S Wolfart; M Kern
Journal:  Clin Oral Investig       Date:  2016-08-12       Impact factor: 3.573

3.  Cost-effectiveness analysis of the single-implant mandibular overdenture versus conventional complete denture: study protocol for a randomized controlled trial.

Authors:  Túlio Eduardo Nogueira; Shahrokh Esfandiari; Cláudio Rodrigues Leles
Journal:  Trials       Date:  2016-11-04       Impact factor: 2.279

4.  Survival and Complications of Single Dental Implants in the Edentulous Mandible Following Immediate or Delayed Loading: A Randomized Controlled Clinical Trial.

Authors:  M Kern; W Att; E Fritzer; S Kappel; R G Luthardt; T Mundt; D R Reissmann; M Rädel; M Stiesch; S Wolfart; N Passia
Journal:  J Dent Res       Date:  2017-10-18       Impact factor: 6.116

5.  Evaluation of patient satisfaction and masticatory performance in mandible single implant-assisted overdenture.

Authors:  Swati Kashyap; Sanjeev Mittal; Navneet Sharma; Urvashi Sukhija; Mohit Kamra; Nitika Gupta
Journal:  Tzu Chi Med J       Date:  2021-04-05

6.  Single dental implant retained mandibular complete dentures--influence of the loading protocol: study protocol for a randomized controlled trial.

Authors:  Nicole Passia; Miha Brezavšček; Elfriede Fritzer; Stefanie Kappel; Thomas Kern; Ralph G Luthardt; Nadine Frfr von Maltzahn; Torsten Mundt; Michael Rädel; Axel von Stein-Lausnitz; Matthias Kern
Journal:  Trials       Date:  2014-05-24       Impact factor: 2.279

7.  The patient general satisfaction of mandibular single-implant overdentures and conventional complete dentures: Study protocol for a randomized crossover trial.

Authors:  Manabu Kanazawa; Mariko Tanoue; Anna Miyayasu; Shin Takeshita; Daisuke Sato; Mari Asami; Thuy Vo Lam; Khaing Myat Thu; Ken Oda; Yuriko Komagamine; Shunsuke Minakuchi; Jocelyne Feine
Journal:  Medicine (Baltimore)       Date:  2018-05       Impact factor: 1.889

8.  One-year prospective clinical study comparing patient satisfaction and masticatory performance of mandibular overdentures supported by one versus two implants.

Authors:  André Gustavo Paleari; Norberto Martins de Oliveira Junior; Danny Omar Mendoza Marin; Larissa Santana Rodriguez; João Neudenir Arioli Filho; Ana Carolina Pero; Marco Antonio Compagnoni
Journal:  J Appl Oral Sci       Date:  2018-10-04       Impact factor: 2.698

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.