Literature DB >> 24890794

Magnetostrictive particle based biosensors for in situ and real-time detection of pathogens in water.

Kewei Zhang1, Liling Fu, Lin Zhang, Z-Y Cheng, Tung-Shi Huang.   

Abstract

Biosensors for in situ detection of pathogenic bacteria in liquid are developed using magnetostrictive particles (MSP) as the sensor platform. The sensing elements used are phage E2 against Salmonella typhimurium, monoclonal antibody against Listeria monocytogenes, polyclonal antibody against Escherichia coli, and polyclonal antibody against Staphylococcus aureus, respectively. These biosensors were characterized in cultures with different populations ranging from 5 × 10(1) to 5 × 10(8)  cfu/mL. It is found that the MSP-based biosensors work well in water and have a rapid response with a response time in minutes, which makes the MSP-based sensors suitable for in situ and real-time detection of pathogenic bacteria in liquid. The experimental results show that all MSP-phage and MSP-antibody biosensors in size of 1.0 mm × 0.3 mm × 15 µm exhibit a detection limit better than 100 cfu/mL. Based on the Hill plot, it is concluded that each bacterial cell is bound onto the sensor surface through about four-to-five sites. When the cultures with low population (<10(6)  cfu/mL) are tested, both MSP-phage and MSP-antibody sensors exhibit the similar response. However, the phage-MSP sensors exhibit a higher capability in the capture of target bacterial cell.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  antibody; biosensor; magnetostrictive particle; pathogen; phage

Mesh:

Substances:

Year:  2014        PMID: 24890794     DOI: 10.1002/bit.25279

Source DB:  PubMed          Journal:  Biotechnol Bioeng        ISSN: 0006-3592            Impact factor:   4.530


  4 in total

1.  Mass Load Distribution Dependence of Mass Sensitivity of Magnetoelastic Sensors under Different Resonance Modes.

Authors:  Kewei Zhang; Lin Zhang; Yuesheng Chai
Journal:  Sensors (Basel)       Date:  2015-08-18       Impact factor: 3.576

2.  Location Dependence of Mass Sensitivity for Acoustic Wave Devices.

Authors:  Kewei Zhang; Yuesheng Chai; Z-Y Cheng
Journal:  Sensors (Basel)       Date:  2015-09-23       Impact factor: 3.576

3.  Effect of Distributed Mass on the Node, Frequency, and Sensitivity of Resonant-Mode Based Cantilevers.

Authors:  Kewei Zhang; Qianke Zhu; Zhe Chen
Journal:  Sensors (Basel)       Date:  2017-07-13       Impact factor: 3.576

Review 4.  A Review of Piezoelectric and Magnetostrictive Biosensor Materials for Detection of COVID-19 and Other Viruses.

Authors:  Fumio Narita; Zhenjin Wang; Hiroki Kurita; Zhen Li; Yu Shi; Yu Jia; Constantinos Soutis
Journal:  Adv Mater       Date:  2020-11-24       Impact factor: 32.086

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.