Literature DB >> 24890694

A novel electrochemical aptasensor for highly sensitive detection of thrombin based on the autonomous assembly of hemin/G-quadruplex horseradish peroxidase-mimicking DNAzyme nanowires.

Shunbi Xie1, Yaqin Chai2, Yali Yuan3, Lijuan Bai3, Ruo Yuan4.   

Abstract

In this work, a new signal amplified strategy was constructed based on isothermal exponential amplification reaction (EXPAR) and hybridization chain reaction (HCR) generating the hemin/G-quadruplex horseradish peroxidase-mimicking DNAzyme (HRP-mimicking DNAzyme) nanowires as signal output component for the sensitive detection of thrombin (TB). We employed EXPAR's ultra-high amplification efficiency to produce a large amount of two hairpin helper DNAs within a minutes. And then the resultant two hairpin helper DNAs could autonomously assemble the hemin/G-quadruplex HRP-mimicking DNAzymes nanowires as the redox-active reporter units on the electrode surface via hybridization chain reaction (HCR). The hemin/G-quadruplex structures simultaneously served as electron transfer medium and electrocatalyst to amplify the signal in the presence of H2O2. Specifically, only when the EXPAR reaction process has occurred, the HCR could be achieved and the hemin/G-quadruplex complexes could be formed on the surface of an electrode to give a detectable signal. The proposed strategy combines the amplification power of the EXPAR, HCR, and the inherent high sensitivity of the electrochemical detection. With such design, the proposed assay showed a good linear relationship within the range of 0.1 pM-50 nM with a detection limit of 33 fM (defined as S/N=3) for TB.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Electrochemical aptasensor; Exponential isothermal amplification; Hemin/G-quadruplex horseradish peroxidase-mimicking DNAzyme; Hybridization chain reaction; Thrombin

Mesh:

Substances:

Year:  2014        PMID: 24890694     DOI: 10.1016/j.aca.2014.04.065

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  Highly sensitive fluorometric determination of thrombin by on-chip signal amplification initiated by terminal deoxynucleotidyl transferase.

Authors:  Dongxiao Wen; Minhui He; Kefeng Ma; Ying Cui; Jinming Kong; Huaixia Yang; Qingyun Liu
Journal:  Mikrochim Acta       Date:  2018-07-19       Impact factor: 5.833

Review 2.  Electrochemical and AFM Characterization of G-Quadruplex Electrochemical Biosensors and Applications.

Authors:  Ana-Maria Chiorcea-Paquim; Ramon Eritja; Ana Maria Oliveira-Brett
Journal:  J Nucleic Acids       Date:  2018-01-31
  2 in total