Literature DB >> 24889775

Left atrial spontaneous echo contrast and thrombus formation at septal puncture during percutaneous mitral valve repair with the MitraClip system of severe mitral regurgitation: a report of two cases.

Mehmet Bilge1, Ayşe Saatci Yaşar, Sina Ali, Recai Alemdar.   

Abstract

Entities:  

Mesh:

Year:  2014        PMID: 24889775     DOI: 10.5152/akd.2014.5355

Source DB:  PubMed          Journal:  Anadolu Kardiyol Derg        ISSN: 1302-8723


× No keyword cloud information.
  4 in total

1.  Thrombus formation during septal puncture.

Authors:  İsa Öner Yüksel; Erkan Köklü; Çağın Mustafa Üreyen; Şakir Arslan
Journal:  Anatol J Cardiol       Date:  2015-05       Impact factor: 1.596

Review 2.  Complications Following Percutaneous Mitral Valve Repair.

Authors:  Livia Gheorghe; Alfonso Ielasi; Benno J W M Rensing; Frank D Eefting; Leo Timmers; Azeem Latib; Martin J Swaans
Journal:  Front Cardiovasc Med       Date:  2019-10-18

Review 3.  Complications of the Percutaneous Mitral Valve Edge-To-Edge Repair: Role of Transesophageal Echocardiography.

Authors:  Guisela Flores; Dolores Mesa; Soledad Ojeda; Javier Suárez de Lezo; Rafael Gonzalez-Manzanares; Guillermo Dueñas; Manuel Pan
Journal:  J Clin Med       Date:  2022-08-14       Impact factor: 4.964

4.  Author's Reply.

Authors:  Mehmet Bilge; Ayşe Saatçi Yaşar
Journal:  Anatol J Cardiol       Date:  2015-05       Impact factor: 1.596