Literature DB >> 24889150

Monitoring nocturnal heart rate with bed sensor.

M Migliorini1, J M Kortelainen, J Pärkkä, M Tenhunen, S L Himanen, A M Bianchi.   

Abstract

INTRODUCTION: This article is part of the Focus Theme of Methods of Information in Medicine on "Biosignal Interpretation: Advanced Methods for Studying Cardiovascular and Respiratory Systems".
OBJECTIVES: The aim of this study is to assess the reliability of the estimated Nocturnal Heart Rate (HR), recorded through a bed sensor, compared with the one obtained from standard electrocardiography (ECG).
METHODS: Twenty-eight sleep deprived patients were recorded for one night each through matrix of piezoelectric sensors, integrated into the mattress, through polysomnography (PSG) simultaneously. The two recording methods have been compared in terms of signal quality and differences in heart beat detection.
RESULTS: On average, coverage of 92.7% of the total sleep time was obtained for the bed sensor, testifying the good quality of the recordings. The average beat-to-beat error of the inter-beat intervals was 1.06%. These results suggest a good overall signal quality, however, considering fast heart rates (HR > 100 bpm), performances were worse: in fact, the sensitivity in the heart beat detection was 28.4% while the false positive rate was 3.8% which means that a large amount of fast beats were not detected.
CONCLUSIONS: The accuracy of the measurements made using the bed sensor has less than 10% of failure rate especially in periods with HR lower than 70 bpm. For fast heart beats the uncertainty increases. This can be explained by the change in morphology of the bed sensor signal in correspondence of a higher HR.

Entities:  

Keywords:  BCG; Nocturnal heart rate; bed sensor; signal quality

Mesh:

Year:  2014        PMID: 24889150     DOI: 10.3414/ME13-02-0053

Source DB:  PubMed          Journal:  Methods Inf Med        ISSN: 0026-1270            Impact factor:   2.176


  6 in total

1.  Improving Bridging from Informatics Theory to Practice.

Authors:  R Haux; S Koch
Journal:  Appl Clin Inform       Date:  2015-12-23       Impact factor: 2.342

2.  Health-Enabling and Ambient Assistive Technologies: Past, Present, Future.

Authors:  R Haux; S Koch; N H Lovell; M Marschollek; N Nakashima; K-H Wolf
Journal:  Yearb Med Inform       Date:  2016-06-30

3.  Unobtrusive Nocturnal Heartbeat Monitoring by a Ballistocardiographic Sensor in Patients with Sleep Disordered Breathing.

Authors:  Matthias Daniel Zink; Christoph Brüser; Björn-Ole Stüben; Andreas Napp; Robert Stöhr; Steffen Leonhardt; Nikolaus Marx; Karl Mischke; Jörg B Schulz; Johannes Schiefer
Journal:  Sci Rep       Date:  2017-10-13       Impact factor: 4.379

4.  Bed Sensor Technology for Objective Sleep Monitoring Within the Clinical Rehabilitation Setting: Observational Feasibility Study.

Authors:  Maartje M S Hendriks; Jaap H van Lotringen; Marije Vos-van der Hulst; Noël L W Keijsers
Journal:  JMIR Mhealth Uhealth       Date:  2021-02-08       Impact factor: 4.773

5.  Performance Evaluation of a Smart Bed Technology against Polysomnography.

Authors:  Farzad Siyahjani; Gary Garcia Molina; Shawn Barr; Faisal Mushtaq
Journal:  Sensors (Basel)       Date:  2022-03-29       Impact factor: 3.576

6.  Physiological Signal Monitoring Bed for Infants Based on Load-Cell Sensors.

Authors:  Won Kyu Lee; Heenam Yoon; Chungmin Han; Kwang Min Joo; Kwang Suk Park
Journal:  Sensors (Basel)       Date:  2016-03-19       Impact factor: 3.576

  6 in total