Literature DB >> 24889143

A systematic review and meta-analysis of experimental clinical evidence on initial aligning archwires and archwire sequences.

S N Papageorgiou1, I Konstantinidis, K Papadopoulou, A Jäger, C Bourauel.   

Abstract

The aim of the study was to assess treatment effects and potential side effects of different archwires used on patients receiving orthodontic therapy. Electronic and manual unrestricted searches were conducted in 19 databases including MEDLINE, Cochrane Library, and Google Scholar until April 2012 to identify randomized controlled trials (RCTs) and quasi-RCTs. After duplicate study selection, data extraction, risk of bias assessment with the Cochrane risk of bias tool, and narrative analysis, mean differences (MDs) with confidence intervals (CIs) of similar studies were pooled using a random-effects model and evaluated with GRADE. A total of 16 RCTs were included assessing different archwire characteristics on 1108 patients. Regarding initial archwires, meta-analysis of two trials found slightly greater irregularity correction with an austenitic-active nickel-titanium (NiTi) compared with an martensitic-stabilized NiTi archwire (corresponding to MD: 1.11 mm, 95% CI: -0.38 to 2.61). Regarding archwire sequences, meta-analysis of two trials found it took patient treated with a sequence of martensitic-active copper-nickel-titanium (CuNiTi) slightly longer to reach the working archwire (MD: 0.54 months, 95% CI: -0.87 to 1.95) compared with a martensitic-stabilized NiTi sequence. However, patients treated with a sequence of martensitic-active CuNiTi archwires reported general greater pain intensity on the Likert scale 4 h and 1 day after placement of each archwire, compared with a martensitic-stabilized NiTi sequence. Although confidence in effect estimates ranged from moderate to high, meta-analyses could be performed only for limited comparisons, while inconsistency might pose a threat to some of them. At this point, there is insufficient data to make recommendations about the majority of initial archwires or for a specific archwire sequence.
© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  aligning archwire; alignment; archwire sequence; bracket; fixed orthodontic treatment; initial archwire; orthodontic archwire

Mesh:

Substances:

Year:  2014        PMID: 24889143     DOI: 10.1111/ocr.12048

Source DB:  PubMed          Journal:  Orthod Craniofac Res        ISSN: 1601-6335            Impact factor:   1.826


  8 in total

1.  Effect of material variation on the biomechanical behaviour of orthodontic fixed appliances: a finite element analysis.

Authors:  Spyridon N Papageorgiou; Ludger Keilig; Istabrak Hasan; Andreas Jäger; Christoph Bourauel
Journal:  Eur J Orthod       Date:  2015-07-14       Impact factor: 3.075

2.  Treatment effects of various prescriptions and techniques for fixed orthodontic appliances : A systematic review.

Authors:  Sophia Mousoulea; Spyridon N Papageorgiou; Theodore Eliades
Journal:  J Orofac Orthop       Date:  2017-04-10       Impact factor: 1.938

3.  Perception of Iraqi Orthodontists and Patients toward Accelerated Orthodontics.

Authors:  Ali M Al-Attar; Samher Al-Shaham; Mushriq Abid
Journal:  Int J Dent       Date:  2021-04-29

4.  Do orthodontists aim to decrease the duration of fixed appliance treatment?

Authors:  Mushriq F Abid; Akram F Alhuwaizi; Ali M Al-Attar
Journal:  J Orthod Sci       Date:  2021-02-19

Review 5.  Outcomes of comprehensive fixed appliance orthodontic treatment: A systematic review with meta-analysis and methodological overview.

Authors:  Spyridon N Papageorgiou; Damian Höchli; Theodore Eliades
Journal:  Korean J Orthod       Date:  2017-09-29       Impact factor: 1.372

6.  Evaluation of the alignment efficiency of nickel-titanium and copper-nickel-titanium archwires in patients undergoing orthodontic treatment over a 12-week period: A single-center, randomized controlled clinical trial.

Authors:  Burcu Aydın; Neslihan Ebru Şenışık; Özgür Koşkan
Journal:  Korean J Orthod       Date:  2018-04-20       Impact factor: 1.372

7.  Supplemental vibrational force does not reduce pain experience during initial alignment with fixed orthodontic appliances: a multicenter randomized clinical trial.

Authors:  Neil R Woodhouse; Andrew T DiBiase; Spyridon N Papageorgiou; Nicola Johnson; Carmel Slipper; James Grant; Maryam Alsaleh; Martyn T Cobourne
Journal:  Sci Rep       Date:  2015-11-27       Impact factor: 4.379

8.  Pain level between clear aligners and fixed appliances: a systematic review.

Authors:  Paula Coutinho Cardoso; Daybelis Gonzalez Espinosa; Paulo Mecenas; Carlos Flores-Mir; David Normando
Journal:  Prog Orthod       Date:  2020-01-20       Impact factor: 2.750

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.