Literature DB >> 24887962

Harmonisation of seven common enzyme results through EQA.

Cas Weykamp, Paul Franck, Jacqueline Klein Gunnewiek, Robert de Jonge, Aldy Kuypers, Douwe van Loon, Herman Steigstra, Christa Cobbaert.   

Abstract

BACKGROUND: Equivalent results between different laboratories enable optimal patient care and can be achieved with harmonisation. We report on EQA-initiated national harmonisation of seven enzymes using commutable samples.
METHODS: EQA samples were prepared from human serum spiked with human recombinant enzymes. Target values were assigned with the IFCC Reference Measurement Procedures. The same samples were included at four occasions in the EQA programmes of 2012 and 2013. Laboratories were encouraged to report IFCC traceable results. A parallel study was done to confirm commutability of the samples.
RESULTS: Of the 223 participating laboratories, 95% reported IFCC traceable results, ranging from 98% (ASAT) to 87% (amylase). Users of Roche and Siemens (97%) more frequently reported in IFCC traceable results than users of Abbott (91%), Beckman (90%), and Olympus (87%). The success of harmonisation, expressed as the recovery of assigned values and the inter-laboratory CV was: ALAT (recovery 100%; inter-lab CV 4%), ASAT (102%; 4%), LD (98%; 3%), CK (101%; 5%), GGT (98%; 4%), AP (96%; 6%), amylase (99%; 4%). There were no significant differences between the manufacturers. Commutability was demonstrated in the parallel study. Equal results in the same sample in the 2012 and 2013 EQA programmes demonstrated stability of the samples.
CONCLUSIONS: The EQA-initiated national harmonisation of seven enzymes, using stable, commutable human serum samples, spiked with human recombinant enzymes, and targeted with the IFCC Reference Measurement Procedures, was successful in terms of implementation of IFCC traceable results (95%), recovery of the target (99%), and inter-laboratory CV (4%).

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24887962     DOI: 10.1515/cclm-2014-0458

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  3 in total

Review 1.  Harmonising Adult Reference Intervals in Australia and New Zealand - the Continuing Story.

Authors:  Gus Koerbin; Jillian R Tate
Journal:  Clin Biochem Rev       Date:  2016-08

2.  EQA/PT scheme to improve the equivalence of enzymatic results between mutual recognition laboratories in Beijing.

Authors:  Qing Tong; Shunli Zhang; Chang Zuo
Journal:  J Clin Lab Anal       Date:  2021-05-05       Impact factor: 2.352

3.  Assessment of patient based real-time quality control on comparative assays for common clinical analytes.

Authors:  Yide Lu; Fan Yang; Dongmei Wen; Kaifeng Shi; Zhichao Gu; Qiuya Lu; Xuefeng Wang; Danfeng Dong
Journal:  J Clin Lab Anal       Date:  2022-08-10       Impact factor: 3.124

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.