Literature DB >> 24887300

Continuous veno-venous hemofiltration to adjust fluid volume excess in septic shock patients reduces intra-abdominal pressure.

Wojciech Dabrowski, Edyta Kotlinska-Hasiec, Daniel Schneditz, Wojciech Zaluska, Ziemowit Rzecki, Bart De Keulenaer, Manu Lng Malbrain.   

Abstract

OBJECTIVE: To analyze the effect and the time course of continuous veno-venous hemofiltration (CVVH) with net ultrafiltration (UF) on intra-abdominal pressure (IAP) body fluid volumes in septic shock patients with acute kidney injury (AKI).
METHODS: Patients were studied at baseline and after 6, 12, 24, 48, 72, and 96 hours of CVVH treatment. IAP was measured via the bladder, and abdominal perfusion pressure (APP) was calculated as mean arterial pressure minus IAP. Fluid volume excess (VE), total body water (TBW), extracellular body water (ECW), and intracellular body water (ICW) were derived from wholebody bioimpedance analysis (BIA).
RESULTS: 30 patients entered final analysis, of which 6 died during CVVH (non-survivors). Fluid VE, TBW, ECW, ICW, and IAP significantly decreased in 24 survivors, whereas these variables remained essentially unchangedin non-survivors. APP slowly increased in survivors, while it did not change in nonsurvivors. IAP strongly correlated with VEin survivors: The lower the IAP, the lower the fluid volume excess.
CONCLUSION: CVVH with net UF successfully reduced IAP, TBW, ECW, and ICW in critically ill patients who survived 96 h of CVVH. Failure to increase APP was associated with fatal outcome, and, finally, IAP correlated with fluid volume excess. BIA could be helpful to monitor fluid status in patients with AKI.

Entities:  

Mesh:

Year:  2014        PMID: 24887300     DOI: 10.5414/CN108015

Source DB:  PubMed          Journal:  Clin Nephrol        ISSN: 0301-0430            Impact factor:   0.975


  6 in total

Review 1.  Bioelectrical impedance analysis during deresuscitation: correlation and agreement with cumulative fluid balance in ICU patients.

Authors:  Martin Ruste; Charlotte Chabanol; Jean-Luc Fellahi; Matthias Jacquet-Lagrèze
Journal:  J Clin Monit Comput       Date:  2022-10-05       Impact factor: 1.977

2.  Intra-abdominal pressure correlates with extracellular water content.

Authors:  Wojciech Dąbrowski; Edyta Kotlinska-Hasiec; Andrzej Jaroszynski; Przemyslaw Zadora; Jacek Pilat; Ziemowit Rzecki; Wojciech Zaluska; Daniel Schneditz
Journal:  PLoS One       Date:  2015-04-07       Impact factor: 3.240

3.  Use of Multifrequency Bioimpedance Analysis in Male Patients with Acute Kidney Injury Who Are Undergoing Continuous Veno-Venous Hemodiafiltration.

Authors:  Harin Rhee; Keum Sook Jang; Min Ji Shin; Jang Won Lee; Il Young Kim; Sang Heon Song; Dong Won Lee; Soo Bong Lee; Ihm Soo Kwak; Eun Young Seong
Journal:  PLoS One       Date:  2015-07-17       Impact factor: 3.240

4.  Bio-electrical impedance analysis for perioperative fluid evaluation in open major abdominal surgery.

Authors:  Adi-Ionut Ciumanghel; Ioana Grigoras; Dimitrie Siriopol; Mihaela Blaj; Daniel-Mihai Rusu; Gabriela Raluca Grigorasi; Alexandru Razvan Igna; Oana Duca; Ianis Siriopol; Adrian Covic
Journal:  J Clin Monit Comput       Date:  2019-06-14       Impact factor: 2.502

Review 5.  Intravenous fluid therapy in the perioperative and critical care setting: Executive summary of the International Fluid Academy (IFA).

Authors:  Manu L N G Malbrain; Thomas Langer; Djillali Annane; Luciano Gattinoni; Paul Elbers; Robert G Hahn; Inneke De Laet; Andrea Minini; Adrian Wong; Can Ince; David Muckart; Monty Mythen; Pietro Caironi; Niels Van Regenmortel
Journal:  Ann Intensive Care       Date:  2020-05-24       Impact factor: 6.925

6.  Perioperative fluid dynamics evaluated by bioelectrical impedance analysis predict infectious surgical complications after esophagectomy.

Authors:  Shuichiro Oya; Hiroharu Yamashita; Ryohei Iwata; Koichiro Kawasaki; Asami Tanabe; Koichi Yagi; Susumu Aikou; Yasuyuki Seto
Journal:  BMC Surg       Date:  2019-12-02       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.