BACKGROUND: Intraoperative Cell Salvage (ICS), hereby referred to 'mechanical red cell salvage', has been widely used in adult elective major surgeries to reduce requirement for homologous red blood cell transfusion and its associated complications. However, amount of free haemoglobin (fHb) from ICS has been shown related to incidence of renal failure. fHb is the most important indicator of quality control of cell salvaged blood, thus monitoring the fHb concentration is imperative to minimise renal injury. However, currently there has been lacking quick biochemical markers to monitor the levels of fHb during ICS. The aim of this study was to screen quick biochemical markers for evaluating the amount of fHb during use of intraoperative cell salvage.Entities:
Mesh:
Substances:
Year: 2014 PMID: 24886505 PMCID: PMC4046511 DOI: 10.1186/1749-8090-9-86
Source DB: PubMed Journal: J Cardiothorac Surg ISSN: 1749-8090 Impact factor: 1.637
Concentration of fHb, clearance rate of fHb and percentage of haemolysis of washed blood
| Concentration of fHb | 0.40 ± 0.27 g/L |
| Clearance rate of fHb | 97% ± 2% |
| Percentage of haemolysis | 0.21% ± 0.11% |
The results of the univariate regression analyses between fHb (g/L) and albumin (ALB, g/L)
| Big flow | fHb = 0.118ALB -0.166 | 0.780 | 0.000 |
| Standard mode | fHb =0.068ALB-0.082 | 0.659 | 0.002 |
| High quality mode | fHb =0.175ALB -0.366 | 0.663 | 0.001 |
| Combined three modes | fHb =0.111ALB -0.108 | 0.638 | 0.000 |
Figure 1In three washing modes, the correlation between fHb and albumin.
The results of the univariate regression analyses between fHb(g/L) and calcium(Ca, mmol/L)
| Big flow | fHb = 1.608Ca + 0.122 | 0.564 | 0.010 |
| standard mode | fHb =0.967Ca + 0.211 | 0.469 | 0.037 |
| High quality mode | fHb =2.676Ca -0.075 | 0.571 | 0.011 |
| Combined three modes | fHb =1.721Ca + 0.091 | 0.514 | 0.000 |
Figure 2In three washing modes, the correlation between fHb and calcium.
The results of the univariate regression analyses between CR and CR
| Big flow | CRfHb = 0.295CRALB + 0.699 | 0.638 | 0.008 |
| Standard mode | CRfHb = 0.324CRALB + 0.675 | 0.896 | 0.000 |
| High quality mode | CRfHb = 0.275CRALB + 0.719 | 0.540 | 0.017 |
| Combined three modes | CRfHb = 0.310CRALB + 0.686 | 0.753 | 0.000 |
Figure 3In three washing modes, the relationship of the clearance rate of fHb and that of albumin.
The results of the univariate regression analyses between CR and CR
| Big flow | CRfHb = 0.261 CRCa + 0.734 | 0.746 | 0.000 |
| Standard mode | CRfHb = 0.111CRCa + 0.894 | 0.760 | 0.000 |
| High quality mode | CRfHb = -0.100CRCa + 0.997 | 0.592 | 0.008 |
| Combined three modes | CRfHb = 0.073 CR Ca + 0.913 | 0.497 | 0.000 |
Figure 4In three washing modes, the relationship of the clearance rate of fHb and that of calcium.