| Literature DB >> 24885387 |
Chun-Yu Chen, Shan-Wei Yang1, Kuan-Yu Lin, Kai-Cheng Lin, Yih-Wen Tarng, Jenn-Huei Renn, Chia-Hsin Lai.
Abstract
BACKGROUND: Surgical managements are recommended for unstable distal clavicle fractures because of a high incidence of nonunion. A variety of methods have been previously reported, but there is no current consensus regarding which method is the most suitable.Entities:
Mesh:
Year: 2014 PMID: 24885387 PMCID: PMC4049442 DOI: 10.1186/1749-799X-9-42
Source DB: PubMed Journal: J Orthop Surg Res ISSN: 1749-799X Impact factor: 2.359
Figure 1Stabilization by single CC suture fixation with Mersilene tape. Surgical procedure: (A) A longitudinal incision was made above the coracoid process. (B) Mersilene tape was passed around the base of the coracoid process and the medial clavicular fragment and was tied to maintain reduction. Radiography of the injured clavicle: (C) Preoperation. (D) Postfixation.
Figure 2Stabilization by hook plate. (A) Preoperative radiography. (B) Postfixation radiography.
Patient demographics and clinical characteristics
| Number of patients | 40 | 28 | |
| Gender, M/F | 28/12 | 16/12 | 0.311a |
| Age (years) | 43.2 (18–75) | 48.3 (28–78) | 0.201b |
| Trauma mechanism, V/F | 24/16 | 20/8 | 0.441a |
| Time from injury to surgery (days) | 1.6 (0–4) | 1.8 (0–5) | 0.791b |
| Follow-up period (months) | 38.2 (24–64) | 37.4 (24–68) | 0.460b |
Data are expressed as mean (range) unless stated otherwise; M single coracoclavicular suture fixation with Mersilene tape, H AO hook plating, V/F vehicular trauma/fall from a height; achi-square test; bindependent sample t test.
Perioperative measurements and clinical results
| Operation time (min) | 43.5 (30 ~ 80) | 65.63 (45 ~ 87) | 0.005a |
| Blood loss (ml) | 22.3 (10 ~ 50) | 55 (25 ~ 100) | 0.010a |
| Complication rate, | 2/40 (5) | 3/28 (10.7) | 0.396b |
| Union rate, | 40/40 (100) | 28/28 (100) |
Data are expressed as mean (range) unless stated otherwise; M single coracoclavicular suture fixation with Mersilene tape, H AO hook plating; aindependent sample t test; bchi-square test.
Scoring for clinical outcome at 2 years postoperatively
| VAS scale | 0.38 (0–2) | 0.5 (0–2) | 0.746 |
| Satisfaction score | 9.62 (7–10) | 9.5 (8–10) | 0.789 |
| UCLA scale | 33.8 (30–35) | 33.1 (29–35) | 0.547 |
| Oxford score | 47.2 (45–48) | 46.9 (45–48) | 0.786 |
Data are expressed as mean (range); M single coracoclavicular suture fixation with Mersilene tape, H AO hook plating.
Figure 3Range of motion of the operated shoulder during follow-up postoperatively.