Literature DB >> 24880207

Muscle thickness measurements to estimate gluteus medius and minimus activity levels.

Angela V Dieterich1, Christine M Pickard2, Geoffrey R Strauss2, Louise E Deshon3, William Gibson4, Janice McKay3.   

Abstract

The clinical assessment of gluteus medius and minimus force sharing requires non-invasive measurements of individual activity levels. Do ultrasound measurements of change of muscle thickness substitute invasive electromyography (EMG)? Isometric hip abduction in 20-80% maximal voluntary isometric contraction (MVIC) was measured using dynamometry, M-mode ultrasound for gluteus medius and minimus thickness and EMG using (1) surface electrodes on gluteus medius, n = 15, (2) fine-wire electrodes in deep gluteus medius and minimus, n = 6. Gluteus medius thickened by 5.0 (SD 2.5) mm at 80% MVIC while gluteus minimus thickness was constant in the surface EMG study and decreased by 1.6 (SD 1.6) mm at the more ventral location in the fine-wire EMG study. Thickness change of gluteus medius enabled prediction of torque (r(2) 0.66) and of surface EMG amplitude (r(2) 0.57). Surface EMG enabled higher torque prediction (r(2) 0.84) than thickness change. Thickness change of gluteus minimus did not enable a practically relevant estimation of torque production. Ultrasound examination revealed a differential thickening behaviour of gluteus medius and minimus which enabled estimation of isometric torque production only for gluteus medius but with lower precision than surface EMG.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Keywords:  Electromyography; Hip; Muscle; Ultrasound

Mesh:

Year:  2014        PMID: 24880207     DOI: 10.1016/j.math.2014.04.014

Source DB:  PubMed          Journal:  Man Ther        ISSN: 1356-689X


  3 in total

1.  Ultrasound Imaging of the Gluteal Muscles During the Y-Balance Test in Individuals With or Without Chronic Ankle Instability.

Authors:  Alexandra F DeJong; L Colby Mangum; Jay Hertel
Journal:  J Athl Train       Date:  2019-12-26       Impact factor: 2.860

2.  Ultrasound Measurement of Skeletal Muscle Contractile Parameters Using Flexible and Wearable Single-Element Ultrasonic Sensor.

Authors:  Ibrahim AlMohimeed; Yuu Ono
Journal:  Sensors (Basel)       Date:  2020-06-27       Impact factor: 3.576

3.  Concurrent Validity and Reliability of Manual Versus Specific Device Transcostal Measurements for Breathing Diaphragm Thickness by Ultrasonography in Lumbopelvic Pain Athletes.

Authors:  Daniel Marugán-Rubio; Jose L Chicharro; Ricardo Becerro-de-Bengoa-Vallejo; Marta Elena Losa-Iglesias; David Rodríguez-Sanz; Davinia Vicente-Campos; Gabriel J Dávila-Sánchez; César Calvo-Lobo
Journal:  Sensors (Basel)       Date:  2021-06-24       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.