Literature DB >> 24879502

Female stress urinary incontinence: clinical efficacy and satisfaction after transobturator adjustable tape sling. An observational longitudinal cohort study.

Tito Silvio Patrelli1, Salvatore Gizzo2, Marco Noventa3, Andrea Dall'Asta4, Andrea Musarò4, Raffaele Faioli4, Giuliano Carlo Zanni5, Giovanni Piantelli4, Adolf Lukanovic6, Alberto Bacchi Modena4, Roberto Berretta4.   

Abstract

We performed an observational longitudinal cohort study on patients affected by stress urinary incontinence (SUI) and surgically treated with a transobturator adjustable tape sling (TOA) in order to evaluate this surgical procedure in terms of efficacy, safety, quality of life (QoL) improvement, and patient satisfaction. For all patients, we recorded: general features, preoperative SUI risk factors, obstetrics history, preoperative urodynamic tests, intraoperative/postoperative complications, number of postoperative sling regulations, postmicturition residue, and hospital stay. All patients were asked to complete the validated short version of the Urogenital Distress Inventory (UDI-6) questionnaire 18 months after discharge to evaluate the efficacy of the TOA system. We added 2 adjunctive items to the UDI-6 in order to evaluate patient satisfaction and QoL. All 77 surgical procedures were performed under locoregional anesthesia without complications. Postoperative TOA regulations were performed in 46.8% of patients immediately after the procedure and in 14.3% during hospitalization. Before discharge, postmicturition residue was negative in 67 cases and less than 50 cc in 10 cases. Mean hospital stay was 2.18 days. From the questionnaire evaluation, we found that after the procedure, 90.9% of patients showed a complete regression of urinary symptoms, 1.3% obtained considerable relief from preoperative symptoms, and 6.6% reported poor or absent symptom improvements; 75.3% of patients were totally satisfied and 5.2% totally disappointed. The possibility of modulating postoperative sling tension and reusing the surgical materials in association with short hospitalization as well as high patient satisfaction render TOA a safe, effective, and low-cost technique for the treatment of female SUI.
© The Author(s) 2014.

Entities:  

Keywords:  UDI-6 questionnaire; patient satisfaction; quality of life; stress urinary incontinence; transobturator adjustable tape

Mesh:

Year:  2014        PMID: 24879502     DOI: 10.1177/1553350614535855

Source DB:  PubMed          Journal:  Surg Innov        ISSN: 1553-3506            Impact factor:   2.058


  2 in total

1.  Adjustable transobturator sling for the treatment of primary stress urinary incontinence.

Authors:  Dmitry Shkarupa; Nikita Kubin; Olga Staroseltseva; Ekaterina Shapovalova
Journal:  Int Urogynecol J       Date:  2017-11-25       Impact factor: 2.894

2.  Female sling: handmade adjustable threads.

Authors:  Luis Gustavo Morato de Toledo; Rafael Ribeiro Zanotti; André Costa Matos
Journal:  Int Braz J Urol       Date:  2021 Jan-Feb       Impact factor: 1.541

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.