Photoelastic stress analysis in mandibular bone surrounding bar-clip overdenture implants.

Mônica Nogueira Pigozzo1, Dalva Cruz Laganá1, Newton Sesma1, Glaís Ferrari de Souza1, Alvaro Luiz Ichi1.   

Abstract

The aim of this in vitro study was to evaluate, using the photoelastic analysis method, the stress distribution in mandibular bone surrounding a bar-clip overdenture when 2 implant angulations were simulated. Two mandibular photoelastic models were manufactured, with 2 implants embedded in the interforaminal region: model 1-PAPI, a photoelastic analysis model with parallel implants; and model 2-PAAI, a photoelastic analysis model with angled implants. A bar-clip retention system and an overdenture were positioned over the implants, and loads of 1.0, 2.0 and 3.0 bars were applied. The resultant stresses that developed in the supporting structure were photoelastically monitored and were recorded photographically. The results showed that there were no similarities in the areas of stress among the photoelastic resin models when the angulation of the implants was evaluated. Model 1-PAPI presented a higher stress concentration at the implant apex, while in model 2-PAAI, there were higher stress concentrations on the mesial and distal implant faces. Within the limitations of this study, it was concluded that the PAPI photoelastic model demonstrated better stress transfer compared to the PAAI model, since the forces oriented along the axis were better absorbed by the bone.

Entities:  

Mesh:

Year:  2013        PMID: 24878673     DOI: 10.1590/s1806-83242013005000034

Source DB:  PubMed          Journal:  Braz Oral Res        ISSN: 1806-8324


  3 in total

1.  Conical connection adjustment in prosthetic abutments obtained by different techniques.

Authors:  Roser Camós-Tena; Tomás Escuin-Henar; Sergi Torné-Duran
Journal:  J Clin Exp Dent       Date:  2019-05-01

Review 2.  Photoelasticity for Stress Concentration Analysis in Dentistry and Medicine.

Authors:  Miriam Marín-Miranda; Ana María Wintergerst; Yoshamin Abnoba Moreno-Vargas; María Lilia Adriana Juárez-López; Cesar Tavera-Ruiz
Journal:  Materials (Basel)       Date:  2022-09-30       Impact factor: 3.748

3.  Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro study.

Authors:  Moustafa Abdou Elsyad; Fathi Abo Setta; Ahmed Samir Khirallah
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904