Literature DB >> 24878234

Real-world performance of the new C3 Gore Excluder stent-graft: 1-year results from the European C3 module of the Global Registry for Endovascular Aortic Treatment (GREAT).

E L G Verhoeven1, A Katsargyris2, P Bachoo3, T Larzon4, R Fisher5, D Ettles6, J R Boyle7, J Brunkwall8, D Böckler9, H-J Florek10, A Stella11, P Kasprzak12, H Verhagen13, V Riambau14.   

Abstract

OBJECTIVES: The European C3 module of the Global Registry for Endovascular Aortic Treatment (GREAT) provides "real-world" outcomes for the new C3 Gore Excluder stent-graft, and evaluates the new deployment mechanism. This report presents the 1-year results from 400 patients enrolled in this registry.
METHODS: Between August 2010 and December 2012, 400 patients (86.8% male, mean age 73.9 ± 7.8 years) from 13 European sites were enrolled in this registry. Patient demographics, treatment indication, case planning, operative details including repositioning and technical results, and clinical outcome were analyzed.
RESULTS: Technical success was achieved in 396/400 (99%) patients. Two patients needed intraoperative open conversion, one for iliac rupture, the second because the stent-graft was pulled down during a cross-over catheterization in an angulated anatomy. Two patients required an unplanned chimney renal stent to treat partial coverage of the left renal artery because of upward displacement of the stent-graft. Graft repositioning occurred in 192/399 (48.1%) patients, most frequently for level readjustment with regard to the renal arteries, and less commonly for contralateral gate reorientation. Final intended position of the stent-graft below the renal arteries was achieved in 96.2% of patients. Thirty-day mortality was two (0.5%) patients. Early reintervention (≤30 days) was required in two (0.5%) patients. Mean follow-up duration was 15.9 ± 8.8 months (range 0-37 months). Late reintervention (>30 days) was required in 26 (6.5%) patients. Estimated freedom from reintervention at 1 year was 95.2% (95% CI 92.3-97%), and at 2 years 91.5% (95% CI 86.8-94.5%). Estimated patient survival at 1 year was 96% (95% CI 93.3-97.6%) and at 2 years 90.6% (95% CI 85.6-93.9%).
CONCLUSIONS: Early real-world experience shows that the new C3 delivery system offers advantages in terms of device repositioning resulting in high deployment accuracy. Longer follow-up is required to confirm that this high deployment accuracy results in improved long-term durability.
Copyright © 2014 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Abdominal aortic aneurysm; Endovascular aneurysm repair; Gore Excluder; Proximal deployment; Repositioning

Mesh:

Year:  2014        PMID: 24878234     DOI: 10.1016/j.ejvs.2014.04.009

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  7 in total

Review 1.  A critical appraisal of endovascular stent-grafts in the management of abdominal aortic aneurysms.

Authors:  Nikolaos Schoretsanitis; Efstratios Georgakarakos; Christos Argyriou; Kiriakos Ktenidis; George S Georgiadis
Journal:  Radiol Med       Date:  2017-01-21       Impact factor: 3.469

2.  Endovascular treatment of genetically linked aortic diseases.

Authors:  D Böckler; K Meisenbacher; A S Peters; C Grond-Ginsbach; M S Bischoff
Journal:  Gefasschirurgie       Date:  2017-01-09

3.  Initial Clinical Experience with the Endologix AFX Unibody Stent Graft System for Treating Patients with Abdominal Aortic Aneurysms: A Case Controlled Comparative Study.

Authors:  George N Kouvelos; Petroula Nana; Vasilios Bouris; Michalis Peroulis; Aikaterini Drakou; Nikolaos Rousas; Athanasios Giannoukas; Miltiadis I Matsagkas
Journal:  Vasc Specialist Int       Date:  2017-03-31

4.  Symptomatic Ipsilateral Limb Twisting Due to Extensive Rotational Re-orientation of the C3 Excluder.

Authors:  Osamu Sakai; Katsuhiko Oka; Tomoya Inoue; Keiichi Kanda; Hitoshi Yaku
Journal:  EJVES Short Rep       Date:  2019-11-14

Review 5.  CT angiography for the assessment of EVAR complications: a pictorial review.

Authors:  Cecilia Gozzo; Giovanni Caruana; Roberto Cannella; Arduino Farina; Dario Giambelluca; Ettore Dinoto; Federica Vernuccio; Antonio Basile; Massimo Midiri
Journal:  Insights Imaging       Date:  2022-01-15

Review 6.  Endografts for the treatment of abdominal aortic aneurysms with a hostile neck anatomy: A systematic review.

Authors:  Christos Pitros; Pietro Mansi; Stavros Kakkos
Journal:  Front Surg       Date:  2022-08-15

7.  Global Post-Market Clinical Follow-up of the Treovance Stent-Graft for Endovascular Aneurysm Repair: One-Year Results From the RATIONALE Registry.

Authors:  Raman Uberoi; Carlo Setacci; Mario Lescan; Antonio Lorido; David Murray; Zoltán Szeberin; Tomasz Zubilewicz; Vincent Riambau; Angsu Chartrungsan; Jörg Tessarek
Journal:  J Endovasc Ther       Date:  2018-10-03       Impact factor: 3.487

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.