Literature DB >> 24876611

Continuous glucose monitors: use of waveform versus glycemic values in the improvements of glucose control, quality of life, and fear of hypoglycemia.

Tomas C Walker1, Carolyn B Yucha2.   

Abstract

How patients are benefitting from continuous glucose monitoring (CGM) remains poorly understood. The focus on numerical glucose values persists, even though access to the glucose waveform and rate of change may contribute more to improved control. This pilot study compared outcomes of patients using CGMs with or without access to the numerical values on their CGM. Ten persons with type 1 diabetes, naïve to CGM use, enrolled in a 12-week study. Subjects were randomly assigned to either unmodified CGM receivers, or to CGM receivers that had their numerical values obscured but otherwise functioned normally. HbA1c, quality of life (QLI-D), and fear of hypoglycemia (HFS) were assessed, at baseline and at week 12. Baseline HbA1c for the entire group was 7.46 ± 1.27%. At week 12 the experimental group HbA1c reduction was 1.5 ± 0.9% (p < .05), the control group's reduction was 0.06 ± 0.61% (p > .05). Repeated measures testing revealed no significant difference in HbA1c reduction between groups. Both groups had reductions in HFS; these reductions were statistically significant within groups (p < .05), but not between groups. QLI-D indices demonstrated improvements (p < .05) in QLI-D total and the health and family subscales, but not between groups. The results of this pilot study suggest that benefits of CGM extend beyond reductions in HbA1c to reductions in fear of hypoglycemia and improvements in quality of life. The display of a numerical glucose value did not improve control when compared to numerically blinded units.
© 2014 Diabetes Technology Society.

Entities:  

Keywords:  continuous glucose monitor; diabetes; fear of hypoglycemia; glucose trending; quality of life; waveform

Mesh:

Substances:

Year:  2014        PMID: 24876611      PMCID: PMC4455439          DOI: 10.1177/1932296814528434

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  22 in total

Review 1.  Impaired awareness of hypoglycaemia: a review.

Authors:  A J Graveling; B M Frier
Journal:  Diabetes Metab       Date:  2010-10       Impact factor: 6.041

2.  Nocturnal hypoglycaemia in type 1 diabetes--frequency and predictive factors.

Authors:  A Woodward; P Weston; I F Casson; G V Gill
Journal:  QJM       Date:  2009-07-02

3.  Analysis of time lags and other sources of error of the DexCom SEVEN continuous glucose monitor.

Authors:  Apurv Kamath; Aarthi Mahalingam; James Brauker
Journal:  Diabetes Technol Ther       Date:  2009-11       Impact factor: 6.118

4.  Continuous home monitoring of glucose: improved glycemic control with real-life use of continuous glucose sensors in adult subjects with type 1 diabetes.

Authors:  Satish K Garg; William C Kelly; Mary K Voelmle; Peter J Ritchie; Peter A Gottlieb; Kim K McFann; Samuel L Ellis
Journal:  Diabetes Care       Date:  2007-09-11       Impact factor: 19.112

5.  Sources of glycemic variability--what type of technology is needed?

Authors:  Jonas Kildegaard; Toke Folke Christensen; Ole Kristian Hejlesen
Journal:  J Diabetes Sci Technol       Date:  2009-07-01

Review 6.  Hypoglycemia is the limiting factor in the management of diabetes.

Authors:  P E Cryer
Journal:  Diabetes Metab Res Rev       Date:  1999 Jan-Feb       Impact factor: 4.876

Review 7.  Hypoglycemia unawareness.

Authors:  Spyridon O Bakatselos
Journal:  Diabetes Res Clin Pract       Date:  2011-08       Impact factor: 5.602

Review 8.  Fear of hypoglycaemia in adults with Type 1 diabetes.

Authors:  T Anderbro; S Amsberg; U Adamson; J Bolinder; P-E Lins; R Wredling; E Moberg; J Lisspers; U-B Johansson
Journal:  Diabet Med       Date:  2010-10       Impact factor: 4.359

9.  The Chronic CARe for diAbeTes study (CARAT): a cluster randomized controlled trial.

Authors:  Anja Frei; Corinne Chmiel; Hansueli Schläpfer; Beatrice Birnbaum; Ulrike Held; Johann Steurer; Thomas Rosemann
Journal:  Cardiovasc Diabetol       Date:  2010-06-15       Impact factor: 9.951

10.  Effect of continuous glucose monitoring on hypoglycemia in type 1 diabetes.

Authors:  Tadej Battelino; Moshe Phillip; Natasa Bratina; Revital Nimri; Per Oskarsson; Jan Bolinder
Journal:  Diabetes Care       Date:  2011-02-19       Impact factor: 19.112

View more
  4 in total

1.  A Systematic Review of Interventions for Health Anxiety Presentations Across Diverse Chronic Illnesses.

Authors:  Danielle Petricone-Westwood; Georden Jones; Brittany Mutsaers; Caroline Séguin Leclair; Christina Tomei; Geneviève Trudel; Andreas Dinkel; Sophie Lebel
Journal:  Int J Behav Med       Date:  2019-02

Review 2.  Psychosocial Aspects of Continuous Glucose Monitoring: Connecting to the Patients' Experience.

Authors:  Thomas Kubiak; Caroline G Mann; Katherine C Barnard; Lutz Heinemann
Journal:  J Diabetes Sci Technol       Date:  2016-06-28

3.  The effect of eye movement desensitization and reprocessing on the fear of hypoglycemia in type 2 diabetic patients: a randomized clinical trial.

Authors:  Mohammadreza Sheikhi; Mohamad Moradi; Saeed Shahsavary; Zainab Alimoradi; Hamid Reza Salimi
Journal:  BMC Psychol       Date:  2020-08-08

4.  Overcoming Barriers to Diabetes Technology in Youth with Type 1 Diabetes and Public Insurance: Cases and Call to Action.

Authors:  Ming Yeh Lee; Molly L Tanenbaum; David M Maahs; Priya Prahalad
Journal:  Case Rep Endocrinol       Date:  2022-03-01
  4 in total