Literature DB >> 24875733

Factors influencing K-wire migration in tension-band wiring of olecranon fractures.

Zubair M Saeed1, Ryan W Trickett2, Alun D Yewlett2, Timothy J W Matthews2.   

Abstract

BACKGROUND: Tension-band wiring is a popular method of internal fixation for simple olecranon fractures. Although fracture union rates and clinical outcomes are good, up to 80% of patients require removal because of prominent/symptomatic metalwork. The current literature remains unclear as to the best orientation of the longitudinal wires to minimize hardware failure. The aim of this study was to determine the surgically modifiable factors related to spontaneous wire pullout.
METHODS: A retrospective review of hospital theater records over a period of 6 years was performed to identify all olecranon tension-band wire procedures. Preoperative radiographs were used to confirm and classify the fracture. Intraoperative and postoperative radiographs were analyzed for a number of wire-associated variables: wire length within the ulna, medullary/cortical position, parallelism of wires, proximal wire prominence, wire angle relative to the ulna, distance from the articular surface, fracture gap, and subsequent pullout.
RESULTS: A total of 182 wires were analyzed. The mean age was 52.5 years, and the mean radiographic follow-up period was 7.3 months. Intramedullary wires had a mean pullout of 5.5 mm compared with 2.4 mm for transcortical wires (P < .0001). A multiple regression model noted 7 independent variables affecting wire pullout: age, bent wires, medullary/transcortical wire positioning, proximal prominence, ulnar shaft angle, distance from the articular surface, and articular step.
CONCLUSION: To minimize postoperative pullout of wires, we suggest anatomic reduction and transcortical wire orientation, without bending, in the subchondral bone close to the articular surface.
Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

Entities:  

Keywords:  Kirschner wires; Olecranon fracture; configuration; hardware failure; radiologic study; tension-band wiring

Mesh:

Year:  2014        PMID: 24875733     DOI: 10.1016/j.jse.2014.02.018

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  12 in total

1.  CORR Insights(®): Factors Associated with Reoperation after Fixation of Displaced Olecranon Fractures.

Authors:  Nash H Naam
Journal:  Clin Orthop Relat Res       Date:  2015-09-11       Impact factor: 4.176

2.  Complications and mortality associated with olecranon fractures in the elderly: a retrospective cohort comparison from a large level one trauma centre.

Authors:  J Parkes; R Limb; S T Quadri; J N Lamb; G Mohrir; A Yousef; R M West; P Cowling
Journal:  Shoulder Elbow       Date:  2021-03-02

3.  Outcomes of embedded rafting k-wire technique for intermediate articular fragment fixation in comminuted olecranon fractures.

Authors:  Jae-Woo Cho; Jong-Keon Oh; Jaewoong Um; Hoon-Sang Sohn
Journal:  Arch Orthop Trauma Surg       Date:  2021-09-23       Impact factor: 2.928

4.  Factors Associated With Reoperation After Fixation of Displaced Olecranon Fractures.

Authors:  Femke M A P Claessen; Yvonne Braun; Rinne M Peters; George Dyer; Job N Doornberg; David Ring
Journal:  Clin Orthop Relat Res       Date:  2015-08-07       Impact factor: 4.176

5.  Comparison of all suture fixation with tension band wiring and plate fixation of the olecranon.

Authors:  Joideep Sunil Phadnis; Alex Vaughan; Toni Luokkala; Jonathon Peters; Jay J Watson; Adam Watts
Journal:  Shoulder Elbow       Date:  2019-02-28

6.  Treatment of displaced transverse fractures of the patella: modified tension band wiring technique with or without augmented circumferential cerclage wire fixation.

Authors:  Tien-Yu Yang; Tsan-Wen Huang; Po-Yao Chuang; Kuo-Chin Huang
Journal:  BMC Musculoskelet Disord       Date:  2018-05-24       Impact factor: 2.362

7.  Biomechanical Comparison of Olecranon Sled Versus Intramedullary Screw Tension Banding for Olecranon Osteotomies.

Authors:  Cameron Kia; Alex G Dukas; Silas T Marshall; Andreas Voss; Elifho Obopilwe; Bruce D Browner; Augustus D Mazzocca
Journal:  Orthop J Sports Med       Date:  2018-12-17

8.  Biomechanical comparison of bi- and tricortical k-wire fixation in tension band wiring osteosynthesis.

Authors:  J Nowotny; F Bischoff; T Ahlfeld; J Goronzy; E Tille; U Nimtschke; A Biewener
Journal:  Eur J Med Res       Date:  2019-10-08       Impact factor: 2.175

9.  Augmented intramedullary screw tension band construct for olecranon fracture reduction and fixation: a review of literature and surgical technique.

Authors:  Joseph T Labrum; Brock D Foster; Douglas R Weikert
Journal:  JSES Int       Date:  2020-06-17

10.  Application of a novel shape-memory alloy concentrator in displaced olecranon fractures: a report of the technique and mid-term clinical results.

Authors:  Demeng Xia; Panyu Zhou; Lei Li; Yan Xia; Zichen Hao; Yuntong Zhang; Shuogui Xu
Journal:  J Orthop Surg Res       Date:  2020-10-02       Impact factor: 2.359

View more