Literature DB >> 24867054

Neonatal resuscitation in resource-limited settings: titrating oxygen delivery without an oxygen blender.

Marta Thio1, Liselotte van Kempen2, Anthony R Rafferty3, Risha Bhatia3, Jennifer A Dawson4, Peter G Davis4.   

Abstract

OBJECTIVE: To test whether 4 commonly used self-inflating bags with a reservoir in situ can reliably deliver different oxygen concentrations (21%-100%) using a portable oxygen cylinder with flows of ≤5 L/min. STUDY
DESIGN: Four self-inflating bags (from Laerdal, Ambu, Parker Healthcare, and Mayo Healthcare) were tested to provide positive pressure ventilation to a manikin at 60 inflations/min by 4 operators. Oxygen delivery was measured for 2 minutes, combining oxygen flows (0.25, 0.5, 1, 5 L/min) and peak inspiratory pressures (PIPs 20-25, 35-40 cmH2O).
RESULTS: Combinations (n=128) were performed twice. Oxygen delivery depended upon device, oxygen flow, and PIP. All self-inflating bags delivered mean oxygen concentrations of <40% with 0.25 L/min, regardless of PIP. Three self-inflating bags delivered ≤40% with flow 0.5 L/min at PIP 35-40 cmH2O, whereas all delivered >40% at PIP 20-25 cmH2O. With 1 L/min, 3 self-inflating bags delivered 40%-60% at PIP 35-40 cmH2O and all delivered >60% at PIP 20-25 cmH2O. With 5 L/min, all self-inflating bags delivered close to or 100%, regardless of PIP. Differences in oxygen delivery between self-inflating bags were statistically significant (P<.001) even when differences were not clinically important.
CONCLUSION: Self-inflating bags with a reservoir in situ can deliver a variety of oxygen concentrations without a blender, from <40% with 0.25 L/min oxygen flow to 100% with 5 L/min. The adjustment of oxygen flow may be a useful method of titrating oxygen in settings where air-oxygen blenders are unavailable.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24867054     DOI: 10.1016/j.jpeds.2014.04.020

Source DB:  PubMed          Journal:  J Pediatr        ISSN: 0022-3476            Impact factor:   4.406


  3 in total

1.  Characterization of teamwork and guideline compliance in prehospital neonatal resuscitation simulations.

Authors:  Nathan Bahr; Trang Kieu Huynh; William Lambert; Jeanne-Marie Guise
Journal:  Resusc Plus       Date:  2022-05-18

2.  Equipment for neonatal resuscitation in a middle-income country: a national survey in Vietnam.

Authors:  Daniele Trevisanuto; Francesco Cavallin; Gaston Arnolda; Tran Dinh Chien; Ornella Lincetto; Ngo Minh Xuan; Nguyen Viet Tien; Nguyen Thi Xuan Hoi; Luciano Moccia
Journal:  BMC Pediatr       Date:  2016-08-20       Impact factor: 2.125

3.  Neonatal resuscitation: evolving strategies.

Authors:  Payam Vali; Bobby Mathew; Satyan Lakshminrusimha
Journal:  Matern Health Neonatol Perinatol       Date:  2015-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.