Literature DB >> 24864120

Characterization of atrial septal defect by simultaneous multiplane two-dimensional echocardiography.

Jackie S McGhie1, Annemien E van den Bosch2, Meindina G Haarman2, Ben Ren2, Jolien W Roos-Hesselink2, Maarten Witsenburg2, Marcel L Geleijnse2.   

Abstract

AIMS: The aim of this study was to assess the value of two-dimensional (2D) transthoracic simultaneous multiplane imaging (SMPI) in the evaluation of suitability for percutaneous atrial septal secundum defect (ASD) closure compared with the golden standard 2D transoesophageal echocardiography (TEE). METHODS AND
RESULTS: Twenty-nine patients with an ASD underwent both SMPI and TEE. Ten patients (34%) were male (age 41 ± 18 years, range 20-74). SMPI assessment of ASD size and rims included xPlane and I-rotate modes. Rims were defined as suitable for ASD percutaneous closure using a cut-off value of 5 mm. There were no significant differences between SMPI in xPlane mode and TEE regarding the sizes of the anterior-posterior dimension (13.7 ± 4.5 vs. 14.5 ± 5.2 mm) and superior-inferior dimension (13.5 ± 3.9 vs. 14.1 ± 5.0 mm, respectively). Agreement for the aortic, atrioventricular, inferior, right upper pulmonary vein, and superior rims was 100, 100, 100, 96, and 96%, respectively.
CONCLUSION: The SMPI technique can reliably assess the dimensions and rim size of a secundum ASD for pre-interventional selection when compared with TEE and has thus the potential to replace TEE. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2014. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  Atrial septal defect; Echocardiography; Simultaneous multiplane imaging

Mesh:

Year:  2014        PMID: 24864120     DOI: 10.1093/ehjci/jeu098

Source DB:  PubMed          Journal:  Eur Heart J Cardiovasc Imaging        ISSN: 2047-2404            Impact factor:   6.875


  4 in total

1.  How to Size ASDs for Percutaneous Closure.

Authors:  Isabelle Boon; Katrien Vertongen; Bernard P Paelinck; Laurent Demulier; An Van Berendoncks; Catherine De Maeyer; Fabienne Marchau; Joseph Panzer; Kristof Vandekerckhove; Daniel De Wolf
Journal:  Pediatr Cardiol       Date:  2017-09-27       Impact factor: 1.655

2.  Transthoracic two-dimensional xPlane and three-dimensional echocardiographic analysis of the site of mitral valve prolapse.

Authors:  Jackie S McGhie; Lotte de Groot-de Laat; Ben Ren; Wim Vletter; René Frowijn; Frans Oei; Marcel L Geleijnse
Journal:  Int J Cardiovasc Imaging       Date:  2015-08-15       Impact factor: 2.357

Review 3.  EDUCATIONAL SERIES IN CONGENITAL HEART DISEASE: Three-dimensional echocardiography in congenital heart disease.

Authors:  John M Simpson; Annemien van den Bosch
Journal:  Echo Res Pract       Date:  2019-05-13

4.  Feasibility of Transcatheter Closure of Large Secundum Atrial Septal Defect with Absent Superior or Inferior Rim.

Authors:  Hussein Abdulwahab; Mohammed Rassul Husain; Khalid A Khalid
Journal:  J Interv Cardiol       Date:  2022-04-04       Impact factor: 2.279

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.