Literature DB >> 24863543

Cardiovascular implantable electronic devices in hemodialysis patients: prevalence and implications for arteriovenous hemodialysis access interventions.

Theodore F Saad1, Waqas Ahmed, Karen Davis, Claudine Jurkovitz.   

Abstract

Cardiovascular implantable electronic devices (CIEDs) are frequently utilized in hemodialysis patients. CIED leads are typically implanted via the subclavian vein resulting in stenosis and venous hypertension. We studied 1235 chronic hemodialysis patients under the care of our nephrology practice. For each, we determined the presence of a CIED, indication for implantable cardioverter-defibrillator (ICD), and type of hemodialysis access. Records were reviewed to identify all interventions performed on the access circuit and the central veins specifically. A CIED was present in 129 patients (10.5%), including ICDs in 75 (6.1%) and pacemakers in 54 (4.4%). The access circuit intervention rate was 1.48/access year (AY) and was similar when a CIED was ipsilateral (1.53/AY) or contralateral (1.44/AY) to arteriovenous access (p = 0.477). The rate of central venous interventions was greater in the ipsilateral (0.59/AY) versus contralateral group (0.28/AY), (p < 0.001). Fifty-four of 59 patients with ipsilateral access and CIED required <2 interventions per AY, but six failed angioplasty and required access ligation. None had superior vena cava stenosis requiring intervention. We conclude that there is a high prevalence of CIEDs in our HD patients. Ipsilateral CIED and arteriovenous access results in higher central venous intervention rates compared with contralateral cases; overall access circuit intervention rates are similar.
© 2014 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2014        PMID: 24863543     DOI: 10.1111/sdi.12249

Source DB:  PubMed          Journal:  Semin Dial        ISSN: 0894-0959            Impact factor:   3.455


  10 in total

1.  Pulsatile tinnitus as a presenting symptom of central venous stenosis secondary to an ipsilateral upper arm arteriovenous PTFE graft.

Authors:  Lloyd Steele; David Flowers; Simon Coles; Paul Gibbs
Journal:  BMJ Case Rep       Date:  2019-07-26

2.  Chronic kidney disease in patients with cardiac rhythm disturbances or implantable electrical devices: clinical significance and implications for decision making-a position paper of the European Heart Rhythm Association endorsed by the Heart Rhythm Society and the Asia Pacific Heart Rhythm Society.

Authors:  Giuseppe Boriani; Irina Savelieva; Gheorghe-Andrei Dan; Jean Claude Deharo; Charles Ferro; Carsten W Israel; Deirdre A Lane; Gaetano La Manna; Joseph Morton; Angel Moya Mitjans; Marc A Vos; Mintu P Turakhia; Gregory Y H Lip
Journal:  Europace       Date:  2015-06-24       Impact factor: 5.214

Review 3.  The cardiovascular-dialysis nexus: the transition to dialysis is a treacherous time for the heart.

Authors:  Kevin Chan; Sharon M Moe; Rajiv Saran; Peter Libby
Journal:  Eur Heart J       Date:  2021-03-31       Impact factor: 29.983

4.  Arteriovenous Vascular Access Selection and Evaluation.

Authors:  Jennifer M MacRae; Matthew Oliver; Edward Clark; Christine Dipchand; Swapnil Hiremath; Joanne Kappel; Mercedeh Kiaii; Charmaine Lok; Rick Luscombe; Lisa M Miller; Louise Moist
Journal:  Can J Kidney Health Dis       Date:  2016-09-27

5.  Hemodialysis Tunneled Catheter Noninfectious Complications.

Authors:  Lisa M Miller; Jennifer M MacRae; Mercedeh Kiaii; Edward Clark; Christine Dipchand; Joanne Kappel; Charmaine Lok; Rick Luscombe; Louise Moist; Matthew Oliver; Pamela Pike; Swapnil Hiremath
Journal:  Can J Kidney Health Dis       Date:  2016-09-27

6.  Arteriovenous Access Failure, Stenosis, and Thrombosis.

Authors:  Jennifer M MacRae; Christine Dipchand; Matthew Oliver; Louise Moist; Charmaine Lok; Edward Clark; Swapnil Hiremath; Joanne Kappel; Mercedeh Kiaii; Rick Luscombe; Lisa M Miller
Journal:  Can J Kidney Health Dis       Date:  2016-09-27

7.  Severity and Extent of Lead-Related Venous Obstruction in More Than 3000 Patients Undergoing Transvenous Lead Extraction.

Authors:  Marek Czajkowski; Wojciech Jacheć; Anna Polewczyk; Jarosław Kosior; Dorota Nowosielecka; Łukasz Tułecki; Paweł Stefańczyk; Andrzej Kutarski
Journal:  Vasc Health Risk Manag       Date:  2022-08-17

8.  Development of Central Venous Stenosis Upon ICD Implantation in Dialysis Patients: A Non-Negligible Issue.

Authors:  Rohit J Timal; Ioannis Karalis; Jose M Montero Cabezas; Joris I Rotmans; Liselotte C R Hensen; Maurits S Buiten; Mihaly K de Bie; Lieselot van Erven; Hein Putter; Martin J Schalij; Ton J Rabelink; J Wouter Jukema
Journal:  Cardiol Cardiovasc Med       Date:  2022-04-14

9.  Impact of transvenous cardiac implantable electronic devices in chronic hemodialysis patients: a single-center, observational comparative study.

Authors:  Seonjeong Jeong; Gi Byoung Nam; Jai Won Chang; Min-Ju Kim; Youngjin Han; Tae-Won Kwon; Yong-Pil Cho
Journal:  BMC Nephrol       Date:  2018-10-20       Impact factor: 2.388

10.  Patency rates of arteriovenous fistulas created before versus after hemodialysis initiation.

Authors:  Seonjeong Jeong; Hyunwook Kwon; Jai Won Chang; Min-Ju Kim; Khaliun Ganbold; Youngjin Han; Tae-Won Kwon; Yong-Pil Cho
Journal:  PLoS One       Date:  2019-01-28       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.