Literature DB >> 24863054

Outcomes of lead revision for myocardial perforation after cardiac implantable electronic device placement.

Xin-Miao Huang1, Hai-Xia Fu, Li Zhong, Michael J Osborn, Samuel J Asirvatham, Lawrence J Sinak, Jiang Cao, Paul A Friedman, Yong-Mei Cha.   

Abstract

INTRODUCTION: Cardiac perforation is an infrequent but potentially life-threatening complication associated with placement of a cardiac implantable electronic device (CIED). The objective of this study was to determine the outcomes of percutaneous lead revision in patients who had lead perforation of the myocardium after CIED placement. METHODS AND
RESULTS: We reviewed records of 1,458 patients who underwent CIED lead extraction or repositioning. Of these, 31 (2.1%) had the procedure performed for lead perforation as a complication of CIED placement. Demographic, clinical, and follow-up characteristics of the patients were analyzed. Mean (SD) patient age was 65 (23) years. Cardiac perforation was detected within 24 hours after implantation in 9 patients, within 1 month in 17, and greater than 1 month in 5. Pericardiocentesis was performed with a pigtail drainage catheter in place before the lead revision in 17 patients (55%) who had pericardial effusion, with or without hemodynamic compromise. All culprit leads were successfully managed with percutaneous lead removal (n = 3 [10%]), new lead placement (n = 12 [38%]), or lead repositioning (n = 16 [52%]). Of the 17 patients with pericardiocentesis before the reoperation, none had tamponade develop; in contrast, 3 of the remaining 14 patients had tamponade develop and required urgent pericardiocentesis. All patients survived without requiring open chest surgery.
CONCLUSION: Percutaneous removal or repositioning of the perforating lead is feasible and appears effective. Placement of a prophylactic pericardial drain catheter may reduce the incidence of urgent pericardiocentesis during or after a procedure.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  cardiac implantable electronic device; lead revision; perforation

Mesh:

Year:  2014        PMID: 24863054     DOI: 10.1111/jce.12457

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  7 in total

1.  Assessment of Cardiac Lead Perforation: Comparison Among Chest Radiography, Transthoracic Echocardiography and Electrocardiography-gated Contrast-enhanced Cardiac CT.

Authors:  Xiang Zhang; Chushan Zheng; Peiwei Wang; Dongye Wang; Boshui Huang; Guozhao Li; Huijun Hu; Zehong Yang; Xiaohui Duan; Shaoxin Zheng; Pinming Liu; Jingfeng Wang; Jun Shen
Journal:  Eur Radiol       Date:  2018-07-17       Impact factor: 5.315

2.  Bilateral Pneumothorax Complicating Pacemaker Implantation, due to Puncture of the Left Subclavian Vein and Electrode Perforation of the Right Atrium.

Authors:  Line Lisbeth Olesen
Journal:  Cureus       Date:  2020-11-02

3.  Selective use of pericardial window and drainage as sole treatment for hemopericardium from penetrating chest trauma.

Authors:  Paul J Chestovich; Christopher F McNicoll; Douglas R Fraser; Purvi P Patel; Deborah A Kuhls; Esmeralda Clark; John J Fildes
Journal:  Trauma Surg Acute Care Open       Date:  2018-08-30

4.  Percutaneous management of atrium and lung perforation: A case report.

Authors:  Xu Zhou; Feng Ze; Ding Li; Xue-Bin Li
Journal:  World J Clin Cases       Date:  2019-12-26       Impact factor: 1.337

5.  Usefulness of right ventriculography compared with computed tomography for ruling out the possibility of lead perforation before lead extraction.

Authors:  Saori Asada; Nobuhiro Nishii; Takayoshi Shinya; Akihito Miyoshi; Yoshimasa Morimoto; Masakazu Miyamoto; Koji Nakagawa; Kazufumi Nakamura; Hiroshi Morita; Hiroshi Ito
Journal:  PLoS One       Date:  2021-03-04       Impact factor: 3.240

6.  Case report: A rare complication after the implantation of a cardiac implantable electronic device: Contralateral pneumothorax with pneumopericardium and pneumomediastinum.

Authors:  Shao-Wei Lo; Ju-Yi Chen
Journal:  Front Cardiovasc Med       Date:  2022-08-18

7.  Outcomes of transvenous lead extraction in patients with lead perforation: A single-center experience.

Authors:  Xu Zhou; Feng Ze; Ding Li; Long Wang; Jihong Guo; Xuebin Li
Journal:  Clin Cardiol       Date:  2020-01-06       Impact factor: 2.882

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.