Literature DB >> 24861873

Development and validation of an LC-MS/MS based method for quantification of 25 hydroxyvitamin D2 and 25 hydroxyvitamin D3 in human serum and plasma.

Stanley Weihua Zhang1, Wenying Jian2, Sheryl Sullivan3, Banu Sankaran3, Richard W Edom2, Naidong Weng2, David Sharkey3.   

Abstract

Vitamin D deficiency is increasing in the general population and has become a serious public health risk globally. As a reliable clinical indicator of vitamin status, 25 hydroxyvitamin D (25(OH)D) has been measured by various methods. However, the accuracy of these measurements has been the subject of considerable debate. Here, we report the development and validation of a liquid chromatography-triple quadrupole mass spectrometry based method for the quantification of 25(OH)D2 and 25(OH)D3 in human serum and plasma samples. Samples were first processed by protein precipitation to release the analytes from the vitamin D binding protein (DBP), followed by a liquid-liquid extraction procedure. Analysis was performed on an LC-MS/MS system which utilized an AB Sciex API 3000 mass spectrometer. A six point calibration curve ranging from 2.5 to 100ng/mL was established for both 25(OH)D2 and 25(OH)D3. A complete method validation was conducted, including intra- and inter-assay accuracy and precision, LLOQ, dilution QC, specificity, recovery, matrix effect, and a thorough stability profile of stock solutions and QC samples. Matching samples of serum and plasma (containing either heparin or EDTA anticoagulant) generated from the same blood samples were tested, and no significant differences in 25(OH)D2 and 25(OH)D3 concentrations were found in these sample matrices. In method comparison, we analyzed 10 serum samples obtained from the Vitamin D External Quality Assessment Scheme (DEQAS), and the total 25(OH)D concentrations measured by our method were very close to the LC-MS/MS Method Mean values provided by DEQAS (average 0.17% bias, R(2)=0.99). However, comparison with the DiaSorin Liaison 25(OH)D TOTAL Assay demonstrated limited correlation between these two methods (R(2)=0.54). In general, concentrations measured by our LC-MS/MS method were roughly 9% higher than those measured by the DiaSorin Liaison assay. The correlation with DiaSorin Liaison measurement was better for samples in the lower concentration range. In summary, we developed and validated an LC-MS/MS based method that can be reliably applied in routine quantification of 25(OH)D2 and 25(OH)D3 in human serum and plasma samples. This method is not suitable for pediatric determinations due to the potential interference of 3-epi 25(OH)D3.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  25-Hydroxyvitamin D; LC–MS/MS; Matrix comparison; Method comparison; Stability; Validation

Mesh:

Substances:

Year:  2014        PMID: 24861873     DOI: 10.1016/j.jchromb.2014.05.006

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  11 in total

1.  A Method for Simultaneous Determination of 25-Hydroxyvitamin D3 and Its 3-Sulfate in Newborn Plasma by LC/ESI-MS/MS after Derivatization with a Proton-Affinitive Cookson-Type Reagent.

Authors:  Tatsuya Higashi; Mai Yokota; Ayaka Goto; Kenji Komatsu; Takahiro Sugiura; Shoujiro Ogawa; Mamoru Satoh; Fumio Nomura
Journal:  Mass Spectrom (Tokyo)       Date:  2016-08-31

Review 2.  Regulation of calcitriol biosynthesis and activity: focus on gestational vitamin D deficiency and adverse pregnancy outcomes.

Authors:  Andrea Olmos-Ortiz; Euclides Avila; Marta Durand-Carbajal; Lorenza Díaz
Journal:  Nutrients       Date:  2015-01-09       Impact factor: 5.717

3.  Determination of ergocalciferol in human plasma after Diels-Alder derivatization by LC-MS/MS and its application to a bioequivalence study.

Authors:  Pritesh Contractor; Abhishek Gandhi; Gajendra Solanki; Priyanka A Shah; Pranav S Shrivastav
Journal:  J Pharm Anal       Date:  2017-05-19

Review 4.  Measurement of circulating 25-hydroxyvitamin D: A historical review.

Authors:  C Le Goff; E Cavalier; J-C Souberbielle; A González-Antuña; E Delvin
Journal:  Pract Lab Med       Date:  2015-05-12

5.  Development of a sensitive HPLC-MS/MS method for 25-hydroxyvitamin D2 and D3 measurement in capillary blood.

Authors:  XianTing Jiao; Yichun Yuan; Xirui Wang; Juan Li; Bin Liu; Tao Yuan; XiaoDan Yu
Journal:  J Clin Lab Anal       Date:  2020-06-26       Impact factor: 2.352

Review 6.  Vitamin D Metabolism and Profiling in Veterinary Species.

Authors:  Emma A Hurst; Natalie Z Homer; Richard J Mellanby
Journal:  Metabolites       Date:  2020-09-15

7.  Simultaneous Determination of Vitamin D and Its Hydroxylated and Esterified Metabolites by Ultrahigh-Performance Supercritical Fluid Chromatography-Tandem Mass Spectrometry.

Authors:  Bárbara Socas-Rodríguez; Veronika Pilařová; Margareta Sandahl; Cecilia Holm; Charlotta Turner
Journal:  Anal Chem       Date:  2022-02-09       Impact factor: 6.986

Review 8.  Vitamin D Metabolites: Analytical Challenges and Clinical Relevance.

Authors:  N Alonso; S Zelzer; G Eibinger; M Herrmann
Journal:  Calcif Tissue Int       Date:  2022-03-03       Impact factor: 4.000

9.  Vitamin D₃ Supplementation Reduces the Symptoms of Upper Respiratory Tract Infection during Winter Training in Vitamin D-Insufficient Taekwondo Athletes: A Randomized Controlled Trial.

Authors:  Hyun Chul Jung; Myong-Won Seo; Sukho Lee; Sung Woo Kim; Jong Kook Song
Journal:  Int J Environ Res Public Health       Date:  2018-09-14       Impact factor: 3.390

10.  Development of an LC-MS Targeted Metabolomics Methodology to Study Proline Metabolism in Mammalian Cell Cultures.

Authors:  Agnieszka Klupczynska; Magdalena Misiura; Wojciech Miltyk; Ilona Oscilowska; Jerzy Palka; Zenon J Kokot; Jan Matysiak
Journal:  Molecules       Date:  2020-10-12       Impact factor: 4.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.