Literature DB >> 24859726

Detection of quiescent cardiac phases in echocardiography data using nonlinear filtering and boundary detection techniques.

Lakshminarayan Ravichandran1, Carson A Wick, James H McClellan, Tian Liu, Srini Tridandapani.   

Abstract

We describe an algorithm to detect cardiac quiescence within a heartbeat using nonlinear filtering and boundary detection techniques in echocardiography images. The motivation for detection of these quiescent phases is to provide improved cardiac gating to obtain motion-artifact-free images of the heart at cardiac computed tomography (CT). Currently, cardiac gating is provided through electrocardiography (ECG), which does not provide information about the instantaneous mechanical state of the heart. Our goal is to test if information about the actual mechanical motion of the heart obtained from B-mode echocardiographic data could potentially be used for gating purposes. The nonlinear filtering algorithm presented involves anisotropic diffusion to smoothen the homogeneous regions of the B-mode images while preserving image edges that represent myocardial boundaries. Following this, we detect the boundary of a particular region of interest (ROI) using a thresholding step. The positional changes of this ROI are then observed for quiescent phases over multiple cardiac cycles using the ECG's R-R interval. In a pilot study, seven subjects were imaged in the apical, four-chamber view, and quiescence of the interventricular septum was primarily observed in the diastolic region of the ECG signal. However, the position and length of quiescence vary across multiple heartbeats for the same individual and for different individuals as well. The center of quiescence for the seven patients ranged from 51 to 84 % and did not show a trend with heart rates, which ranged from 54 to 83 beats per minute. The gating intervals based on such analysis of echocardiographic signals could potentially optimize cardiac CT gating.

Entities:  

Mesh:

Year:  2014        PMID: 24859726      PMCID: PMC4171429          DOI: 10.1007/s10278-014-9702-3

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  15 in total

1.  Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT.

Authors:  S Achenbach; S Ulzheimer; U Baum; M Kachelriess; D Ropers; T Giesler; W Bautz; W G Daniel; W A Kalender; W Moshage
Journal:  Circulation       Date:  2000-12-05       Impact factor: 29.690

2.  Optimal ECG trigger point in electron-beam CT studies: three methods for minimizing motion artifacts.

Authors:  S Mao; M J Budoff; L Bin; S C Liu
Journal:  Acad Radiol       Date:  2001-11       Impact factor: 3.173

Review 3.  Assessment of coronary artery disease by cardiac computed tomography: a scientific statement from the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology.

Authors:  Matthew J Budoff; Stephan Achenbach; Roger S Blumenthal; J Jeffrey Carr; Jonathan G Goldin; Philip Greenland; Alan D Guerci; Joao A C Lima; Daniel J Rader; Geoffrey D Rubin; Leslee J Shaw; Susan E Wiegers
Journal:  Circulation       Date:  2006-10-02       Impact factor: 29.690

4.  Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose.

Authors:  James P Earls; Elise L Berman; Bruce A Urban; Charlene A Curry; Judith L Lane; Robert S Jennings; Colin C McCulloch; Jiang Hsieh; John H Londt
Journal:  Radiology       Date:  2008-01-14       Impact factor: 11.105

5.  Speckle reducing anisotropic diffusion.

Authors:  Yongjian Yu; Scott T Acton
Journal:  IEEE Trans Image Process       Date:  2002       Impact factor: 10.856

6.  Nonlinear anisotropic filtering of MRI data.

Authors:  G Gerig; O Kubler; R Kikinis; F A Jolesz
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

7.  A half century of selective coronary arteriography.

Authors:  Albert V G Bruschke; William C Sheldon; Earl K Shirey; William L Proudfit
Journal:  J Am Coll Cardiol       Date:  2009-12-01       Impact factor: 24.094

8.  Digital image enhancement and noise filtering by use of local statistics.

Authors:  J S Lee
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  1980-02       Impact factor: 6.226

9.  A model for radar images and its application to adaptive digital filtering of multiplicative noise.

Authors:  V S Frost; J A Stiles; K S Shanmugan; J C Holtzman
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  1982-02       Impact factor: 6.226

Review 10.  Heart disease and stroke statistics--2013 update: a report from the American Heart Association.

Authors:  Alan S Go; Dariush Mozaffarian; Véronique L Roger; Emelia J Benjamin; Jarett D Berry; William B Borden; Dawn M Bravata; Shifan Dai; Earl S Ford; Caroline S Fox; Sheila Franco; Heather J Fullerton; Cathleen Gillespie; Susan M Hailpern; John A Heit; Virginia J Howard; Mark D Huffman; Brett M Kissela; Steven J Kittner; Daniel T Lackland; Judith H Lichtman; Lynda D Lisabeth; David Magid; Gregory M Marcus; Ariane Marelli; David B Matchar; Darren K McGuire; Emile R Mohler; Claudia S Moy; Michael E Mussolino; Graham Nichol; Nina P Paynter; Pamela J Schreiner; Paul D Sorlie; Joel Stein; Tanya N Turan; Salim S Virani; Nathan D Wong; Daniel Woo; Melanie B Turner
Journal:  Circulation       Date:  2012-12-12       Impact factor: 29.690

View more