A fast minimum variance beamforming method using principal component analysis.

Kyuhong Kim, Suhyun Park, Jungho Kim, Sung-Bae Park, MooHo Bae.   

Abstract

Minimum variance (MV) beamforming has been studied for improving the performance of a diagnostic ultrasound imaging system. However, it is not easy for the MV beamforming to be implemented in a real-time ultrasound imaging system because of the enormous amount of computation time associated with the covariance matrix inversion. In this paper, to address this problem, we propose a new fast MV beamforming method that almost optimally approximates the MV beamforming while reducing the computational complexity greatly through dimensionality reduction using principal component analysis (PCA). The principal components are estimated offline from pre-calculated conventional MV weights. Thus, the proposed method does not directly calculate the MV weights but approximates them by a linear combination of a few selected dominant principal components. The combinational weights are calculated in almost the same way as in MV beamforming, but in the transformed domain of beamformer input signal by the PCA, where the dimension of the transformed covariance matrix is identical to the number of some selected principal component vectors. Both computer simulation and experiment were carried out to verify the effectiveness of the proposed method with echo signals from simulation as well as phantom and in vivo experiments. It is confirmed that our method can reduce the dimension of the covariance matrix down to as low as 2 × 2 while maintaining the good image quality of MV beamforming.

Year:  2014        PMID: 24859657     DOI: 10.1109/TUFFC.2014.2989

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  3 in total

1.  Improvement of penetration of modified amplitude and phase estimation beamformer.

Authors:  Hideyuki Hasegawa
Journal:  J Med Ultrason (2001)       Date:  2016-07-21       Impact factor: 1.314

2.  Eigenspace-based beamformer using oblique signal subspace projection for ultrasound plane-wave imaging.

Authors:  Saeid Aliabadi; Yuanyuan Wang; Jinhua Yu; Jinxin Zhao; Wei Guo; Shun Zhang
Journal:  Biomed Eng Online       Date:  2016-11-24       Impact factor: 2.819

3.  A new method for assessing the performance of signal processing filters in suppressing the side lobe level.

Authors:  Mok Kun Jeong; Sung Jae Kwon
Journal:  Ultrasonography       Date:  2020-07-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.