The effect of personal protective equipment on emergency airway management by emergency physicians: a mannequin study.

Chung-Cheng Wang1, Chung-Hsien Chaou, Chiung-Yao Tseng, Chih-Chuan Lin.   

Abstract

OBJECTIVE: Emergency medical personnel are at risk of secondary contamination when treating victims of chemical-biological-radiological-nuclear incidents. Hence, it is crucial to train them on the appropriate management of patients involved in chemical-biological-radiological-nuclear incidents. Personal protective equipment (PPE) plays an important role in treating patients suffering from various types of poisoning. However, very few studies have examined whether the use of PPE impedes airway management in an emergency department setting. The present study evaluated the effect of PPE on physicians' performance of emergency airway management using mannequins.
METHODS: Forty emergency physicians with 1-4 years of experience participated, and were divided by years of experience (1-2 vs. 3-4 years). Each participant both intubated a tracheal tube and inserted a laryngeal mask airway into a mannequin, with and without wearing protection using preassembled intubation aids. The intubation time for both methods was assessed along with participants' preferences and experiences in airway management.
RESULTS: The mean (SD) times to successful tracheal tube/mask placement with and without protection were similar [tracheal tube: 17.86 s (6.38) vs. 17.83 s (11.13), P=0.99; laryngeal mask: 10.51 s (4.39) vs. 9.65 s (3.29), P=0.32].
CONCLUSION: Protective equipment had no effect on physicians' emergency airway placement time. The effect of wearing PPE is limited if postintubation care is excluded from the evaluation. Furthermore, intubation experience influenced participants' preferred approach for airway management.

Entities:  

Mesh:

Year:  2016        PMID: 24858914     DOI: 10.1097/MEJ.0000000000000157

Source DB:  PubMed          Journal:  Eur J Emerg Med        ISSN: 0969-9546            Impact factor:   2.799


  1 in total

1.  Maintenance of Skill Proficiency for Emergency Skills With and Without Adjuncts Despite the Use of Level C Personal Protective Equipment.

Authors:  Harsh Sule; Miriam Kulkarni; Gregory Sugalski; Tiffany Murano
Journal:  Cureus       Date:  2020-03-27