Bhupendra Pratap Singh1, Amit Kumar2, Deepak Singh2, Monika Punia2, Krishan Kumar2, Vinod Kumar Jain2.
Abstract
This study investigates the levels of ozone concentration along with an ultraviolet (UV) and visible spectral radiation at eight photocopy centers in an academic institute, Delhi. Sampling was done in two types of locations, i.e., basement photocopy centers (BPC) and ground floor photocopy centers (GPC) for 8h. Measurements of levels of ozone, UV and visible radiation were done by ozone analyzer, UV radiometer and Field spectra instrument, respectively. Results show that the hourly mean concentration of ozone was observed to be in the range of 1.8-10.0 ppb and 5.3-45.8 ppb for BPC and GPC, respectively. In terms UV radiations, energy lies between 5.0×10(-3) and 7.0×10(-3) mW/cm(2) for ultraviolet A (UVA), 1.0×10(-3) and 2.0×10(-3) mW/cm(2) for ultraviolet B (UVB) and 6.0×10(-3) and 8.0×10(-3) mW/cm(2) for ultraviolet C (UVC). Correlation between the UV radiations and ozone production observed was statistically insignificant. To know the health hazard occurred to the workers, the standard erythema dose (SED) value was calculated for emitting UV radiation. The SED was estimated to be in the range of 0.02-0.04 and 0.02-0.32 for direct and indirect methods which is less than the guideline prescribed by Commission Internationale del' Eclairage (CIE). In nutshell, person involved in photocopy operation for their livelihood must be trained and should have knowledge for the long term gradual build up health problems due to ozone and UV production from photocopier. The manufactures should be ultimated with the significant ozone production, so that photocopier machine can be redesigned.Entities:
Keywords: Ozone; Photocopier machine; Standard erythema dose; UV radiation
Mesh:
Substances:
Year: 2014 PMID: 24857892 DOI: 10.1016/j.jhazmat.2014.04.049
Source DB: PubMed Journal: J Hazard Mater ISSN: 0304-3894 Impact factor: 10.588