The impact of coronal alignment on distal radioulnar joint stability following distal radius fracture.

Christopher J Dy1, Eugene Jang1, Samuel A Taylor1, Kathleen N Meyers1, Scott W Wolfe2.   

Abstract

PURPOSE: Shift of the distal fragment of a distal radius fracture (DRF) in the coronal plane (coronal shift) may compromise the contributions of the distal oblique bundle (DOB) of the interosseous membrane to distal radioulnar joint (DRUJ) stability. The purpose of the study was to test our hypothesis that coronal shift of the distal fragment would increase dorsal-volar DRUJ displacement in response to applied load.
METHODS: A distal radius osteotomy was performed proximal to the sigmoid notch base and the ulnar styloid was cut (to simulate triangular fibrocartilage complex detachment) in 10 cadaveric specimens. A volarly placed plate was used to shift the distal radius fragment radially in 2-mm increments. A mechanical testing apparatus applied a 20 N load to the distal fragment perpendicular to the volar cortex with the forearm in neutral, 60° pronation, and 60° supination. Dorsal-volar displacement of the radius relative to the fixed ulna was measured in the control state (DRF and ulnar styloid anatomically fixed) and in 3 positions (anatomical reduction, 2-mm coronal shift, 4-mm coronal shift) with ulnar styloid displacement. The specimens were dissected post hoc to evaluate for a distinct DOB (thickness, > 0.5 mm). Dorsal-volar DRUJ displacement was compared among testing and control states using analysis of variance.
RESULTS: In specimens with a distinct DOB, 2-mm coronal shift significantly increased dorsal-volar DRUJ displacement. However, there was no difference in DRUJ displacement between 4-mm coronal shift and control state. Coronal shift did not affect dorsal-volar DRUJ displacement in specimens without a distinct DOB.
CONCLUSIONS: In the setting of an ulnar styloid fracture, a 2-mm (but not a 4-mm) coronal shift of the DRF is associated with increased dorsal-volar DRUJ displacement in specimens with a distinct DOB, but not in specimens without a distinct DOB. CLINICAL RELEVANCE: Awareness of the importance of coronal shift may aid in prevention of DRUJ instability associated with DRF, especially in patients with a DOB.
Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Distal interosseous membrane; coronal shift; distal oblique bundle; distal radioulnar joint; distal radius

Mesh:

Year:  2014        PMID: 24857823     DOI: 10.1016/j.jhsa.2014.03.041

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  9 in total

1.  A Biomechanical Perspective on Distal Radioulnar Joint Instability.

Authors:  Shohei Omokawa; Akio Iida; Kenji Kawamura; Yasuaki Nakanishi; Takamasa Shimizu; Tsutomu Kira; Tadanobu Onishi; Naoki Hayami; Yasuhito Tanaka
Journal:  J Wrist Surg       Date:  2017-03-22

2.  Dorsal Lunate Facet Fracture Reduction Using a Bone Reduction Forceps.

Authors:  Jonathan Lans; Josefina Alvarez; Amir R Kachooei; Sezai Ozkan; Jesse B Jupiter
Journal:  J Wrist Surg       Date:  2018-10-03

3.  Surgical versus conservative management of distal radius fracture with coronal shift; a randomized controlled trial.

Authors:  Mohammad Dehghani; Hadi Ravanbod; Mohammadreza Piri Ardakani; Mohammad Hossein Tabatabaei Nodushan; Shakiba Dehghani; Meghdad Rahmani
Journal:  Int J Burns Trauma       Date:  2022-04-15

Review 4.  Distal Radioulnar Joint Instability: Diagnosis and Treatment.

Authors:  E Carlos Rodríguez-Merchán; Babak Shojaie; Amir R Kachooei
Journal:  Arch Bone Jt Surg       Date:  2022-01

Review 5.  Arthroscopic treatment for ulnar-sided TFCC-tears.

Authors:  L Mannil; W Martin; J Dahmen; T Witte; P G Juten; F Deneken; M Räder; H H Homann
Journal:  Eur J Trauma Emerg Surg       Date:  2015-11-13       Impact factor: 3.693

6.  Intramedullary Fixation of Distal Radius Fractures Using CAGE-DR Implant.

Authors:  Schneider K Rancy; Stephanie D Malliaris; Eric A Bogner; Scott W Wolfe
Journal:  J Wrist Surg       Date:  2018-09-18

7.  Distal Radioulnar Joint Instability: Assessment of Three Intraoperative Radiographic Stress Tests.

Authors:  Joseph A Gil; Lindsay R Kosinski; Kalpit N Shah; Julia A Katarincic; Sanjeev Kakar
Journal:  Hand (N Y)       Date:  2019-10-20

8.  Magnetic resonance imaging evaluation of the distal oblique bundle in the distal interosseous membrane of the forearm.

Authors:  Yeon Ho Kim; Hyun Sik Gong; Jin Woo Park; Hyun Kyung Yang; Kahyun Kim; Goo Hyun Baek
Journal:  BMC Musculoskelet Disord       Date:  2017-01-26       Impact factor: 2.362

9.  Imaging study of coronal structural matching of the distal radius in normal adults.

Authors:  Xin Zhang; Feng Yuan; Yong Yin; Jian Fan
Journal:  BMC Med Imaging       Date:  2020-04-03       Impact factor: 1.930

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.