Literature DB >> 24856397

Prussian blue-gold nanoparticles-ionic liquid functionalized reduced graphene oxide nanocomposite as label for ultrasensitive electrochemical immunoassay of alpha-fetoprotein.

Qi Gao1, Na Liu1, Zhanfang Ma2.   

Abstract

In this work, poly(diallyldimethylammonium chloride) (PDDA) protected Prussian blue/gold nanoparticles/ionic liquid functionalized reduced graphene oxide (IL-rGO-Au-PDDA-PB) nanocomposite was fabricated. The resulting nanocomposite exhibited high biocompatibility, conductivity and catalytic activity. To assess the performance of the nanocomposite, a sensitive sandwich-type immunosensor was constructed for detecting alpha-fetoprotein (AFP). Greatly enhanced sensitivity for this immunosensor was based on triple signal amplification strategies. Firstly, IL-rGO modified electrode was used as biosensor platform to capture a large amount of antibody due to its increased surface area, thus amplifying the detection response. Secondly, a large number of Au-PDDA-PB was conjugated on the surface of IL-rGO, which meant the enrichment of the signal and the more immobilization of label antibody. Finally, the catalytic reaction between H2O2 and the IL-rGO-Au-PDDA-PB nanocomposite further enhanced the signal response. The signals increased linearly with AFP concentrations in the range of 0.01-100 ng mL(-1). The detection limit for AFP was 4.6 pg mL(-1). The immunosensor showed high sensitivity, excellent selectivity and good stability. Moreover, the immunosensor was applied to the analysis of AFP in serum sample with satisfactory result.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Alpha-fetoprotein; Electrochemical immunosensor; Ionic liquid functionalized reduced graphene oxide; Prussian blue

Mesh:

Substances:

Year:  2014        PMID: 24856397     DOI: 10.1016/j.aca.2014.04.045

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

Review 1.  Electrochemical sensors and biosensors based on nanomaterials and nanostructures.

Authors:  Chengzhou Zhu; Guohai Yang; He Li; Dan Du; Yuehe Lin
Journal:  Anal Chem       Date:  2014-12-19       Impact factor: 6.986

2.  A label-free immunosensor based on PHEMA/graphene oxide nanocomposite for simultaneous electrochemical determination of alpha fetoprotein.

Authors:  Ying Liang; Xiaoqing Zhao; Na Wang; Jing Wang; Hou Chen; Liangjiu Bai; Wenxiang Wang
Journal:  RSC Adv       Date:  2019-06-03       Impact factor: 4.036

Review 3.  Recent Progress in Nanomaterial-Based Electrochemical Biosensors for Cancer Biomarkers: A Review.

Authors:  Baozhen Wang; Uichi Akiba; Jun-Ichi Anzai
Journal:  Molecules       Date:  2017-06-24       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.