Literature DB >> 24854903

Evaluating four-dimensional time-lapse electrical resistivity tomography for monitoring DNAPL source zone remediation.

Christopher Power1, Jason I Gerhard2, Marios Karaoulis3, Panagiotis Tsourlos4, Antonios Giannopoulos5.   

Abstract

Practical, non-invasive tools do not currently exist for mapping the remediation of dense non-aqueous phase liquids (DNAPLs). Electrical resistivity tomography (ERT) exhibits significant potential but has not yet become a practitioner's tool due to challenges in interpreting the survey results at real sites. This study explores the effectiveness of recently developed four-dimensional (4D, i.e., 3D space plus time) time-lapse surface ERT to monitor DNAPL source zone remediation. A laboratory experiment demonstrated the approach for mapping a changing NAPL distribution over time. A recently developed DNAPL-ERT numerical model was then employed to independently simulate the experiment, providing confidence that the DNAPL-ERT model is a reliable tool for simulating real systems. The numerical model was then used to evaluate the potential for this approach at the field scale. Four DNAPL source zones, exhibiting a range of complexity, were initially simulated, followed by modeled time-lapse ERT monitoring of complete DNAPL remediation by enhanced dissolution. 4D ERT inversion provided estimates of the regions of the source zone experiencing mass reduction with time. Results show that 4D time-lapse ERT has significant potential to map both the outline and the center of mass of the evolving treated portion of the source zone to within a few meters in each direction. In addition, the technique can provide a reasonable, albeit conservative, estimate of the DNAPL volume remediated with time: 25% underestimation in the upper 2m and up to 50% underestimation at late time between 2 and 4m depth. The technique is less reliable for identifying cleanup of DNAPL stringers outside the main DNAPL body. Overall, this study demonstrates that 4D time-lapse ERT has potential for mapping where and how quickly DNAPL mass changes in real time during site remediation.
Copyright © 2014 Elsevier B.V. All rights reserved.

Keywords:  4D time-lapse monitoring; DNAPL; Electrical resistivity tomography; Geophysics; Remediation

Mesh:

Substances:

Year:  2014        PMID: 24854903     DOI: 10.1016/j.jconhyd.2014.04.004

Source DB:  PubMed          Journal:  J Contam Hydrol        ISSN: 0169-7722            Impact factor:   3.188


  1 in total

1.  Polyelectrolyte-grafted Ti3C2-MXenes stable in extreme salinity aquatic conditions for remediation of contaminated subsurface environments.

Authors:  Sehyeong Lim; Hyunsu Park; Jin Hyung Kim; Jeewon Yang; Chaesu Kwak; Jieun Kim; Seoung Young Ryu; Joohyung Lee
Journal:  RSC Adv       Date:  2020-07-09       Impact factor: 4.036

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.