Literature DB >> 24854873

Anterior-posterior versus anterior-lateral electrode position for external electrical cardioversion of atrial fibrillation: a meta-analysis of randomized controlled trials.

Baowei Zhang1, Xiaoli Li1, Dongli Shen1, Ya Zhen1, Aibin Tao1, Guohui Zhang2.   

Abstract

BACKGROUND: Several clinical trials have shown inconsistent results regarding the effect of electrode positions on the success of electrical cardioversion. AIMS: The aim of this meta-analysis was to investigate the effect of the anterior-posterior electrode position on the success of electrical cardioversion in patients undergoing external electrical cardioversion for atrial fibrillation.
METHODS: Pubmed, EMBASE, the Cochrane Library and the Chinese National Knowledge Infrastructure were searched for randomized controlled trials. The effect of the anterior-posterior electrode position on cardioversion success is presented as a risk ratio with 95% confidence interval.
RESULTS: Ten trials with 1281 patients were included in the analysis. The anterior-posterior electrode position had no advantages in terms of success of electrical cardioversion for atrial fibrillation compared with the anterior-lateral electrode position (risk ratio 1.02, 95% confidence interval 0.96-1.09; P=0.50). Subgroup analysis showed that patients with a left atrium diameter≤45 mm and lone atrial fibrillation might derive benefits from the anterior-posterior electrode position in terms of success of cardioversion. No evidence of publication bias was detected.
CONCLUSIONS: The present analysis suggests that only patients with a left atrium diameter≤45 mm and lone atrial fibrillation might derive benefits from the anterior-posterior electrode position compared with the anterior-lateral electrode position during external electrical cardioversion for atrial fibrillation. However, there was insufficient evidence to support any advantages for the anterior-posterior electrode position in other situations.
Copyright © 2014 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Atrial fibrillation; Cardioversion électrique; Electrical cardioversion; Electrode position; Fibrillation atriale; Meta-analysis; Méta-analyse; Position de l’électrode

Mesh:

Year:  2014        PMID: 24854873     DOI: 10.1016/j.acvd.2014.04.002

Source DB:  PubMed          Journal:  Arch Cardiovasc Dis        ISSN: 1875-2128            Impact factor:   2.340


  3 in total

1.  Esophageal electric fields are predictive of atrial cardioversion success-a finite element analysis.

Authors:  David A Fitch; Amy L de Jongh Curry
Journal:  Ann Transl Med       Date:  2015-08

Review 2.  A Systematic Review of the Transthoracic Impedance during Cardiac Defibrillation.

Authors:  Yasmine Heyer; Daniela Baumgartner; Christian Baumgartner
Journal:  Sensors (Basel)       Date:  2022-04-06       Impact factor: 3.576

Review 3.  [Adult advanced life support].

Authors:  Jasmeet Soar; Bernd W Böttiger; Pierre Carli; Keith Couper; Charles D Deakin; Therese Djärv; Carsten Lott; Theresa Olasveengen; Peter Paal; Tommaso Pellis; Gavin D Perkins; Claudio Sandroni; Jerry P Nolan
Journal:  Notf Rett Med       Date:  2021-06-08       Impact factor: 0.826

  3 in total