Literature DB >> 24852735

Experimental study of hybrid-knife endoscopic submucosal dissection (ESD) versus standard ESD in a Western country.

Joaquín De-la-Peña, Ángel Calderón, José Miguel Esteban, Leopoldo López-Rosés, David Martínez-Ares, Óscar Nogales, Aitor Orive-Calzada, Sarbelio Rodríguez, Eloy Sánchez-Hernández, Juan Vila, Gloria Fernández-Esparrach.   

Abstract

BACKGROUND: Endoscopic submucosal dissection (ESD) is an effective but time-consuming treatment for early neoplasia that requires a high level of expertise.
OBJECTIVE: The objective of this study was to assess the efficacy and learning curve of gastric ESD with a hybrid knife with high pressure water jet and to compare with standard ESD.
MATERIAL AND METHODS: We performed a prospective non survival animal study comparing hybrid-knife and standard gastric ESD. Variables recorded were: Number of en-bloc ESD, number of ESD with all marks included (R0), size of specimens, time and speed of dissection and adverse events. Ten endoscopists performed a total of 50 gastric ESD (30 hybrid-knife and 20 standard).
RESULTS: Forty-six (92 %) ESD were en-bloc and 25 (50 %) R0 (hybrid-knife: n = 13, 44 %; standard: n = 16, 80 %; p = 0.04). Hybrid-knife ESD was faster than standard (time: 44.6 +/- 21.4 minutes vs. 68.7 +/- 33.5 minutes; p = 0.009 and velocity: 20.8 +/- 9.2 mm(2)/min vs. 14.3 +/- 9.3 mm(2)/min (p = 0.079). Adverse events were not different. There was no change in speed with any of two techniques (hybrid-knife: From 20.33 +/- 15.68 to 28.18 +/- 20.07 mm(2)/min; p = 0.615 and standard: From 6.4 +/- 0.3 to 19.48 +/- 19.21 mm(2)/min; p = 0.607). The learning curve showed a significant improvement in R0 rate in the hybrid-knife group (from 30 % to 100 %).
CONCLUSION: despite the initial performance of hybrid-knife ESD is worse than standard ESD, the learning curve with hybrid knife ESD is short and is associated with a rapid improvement. The introduction of new tools to facilitate ESD should be implemented with caution in order to avoid a negative impact on the results.

Entities:  

Mesh:

Year:  2014        PMID: 24852735     DOI: 10.4321/s1130-01082014000200005

Source DB:  PubMed          Journal:  Rev Esp Enferm Dig        ISSN: 1130-0108            Impact factor:   2.086


  2 in total

1.  Waterjet submucosal dissection of porcine esophagus with the HybridKnife and ERBEJET 2 system: a pilot study.

Authors:  Daisuke Akutsu; Hideo Suzuki; Toshiaki Narasaka; Masahiko Terasaki; Tsuyoshi Kaneko; Hirofumi Matsui; Yuji Mizokami; Ichinosuke Hyodo
Journal:  Endosc Int Open       Date:  2017-01

2.  Comparisons of outcomes between ProKnife injection endoscopic submucosal dissection and conventional endoscopic submucosal dissection for large gastric lesions in ex vivo porcine model study: A randomized controlled trial.

Authors:  Mitsuru Esaki; Eikichi Ihara; Misato Esaki; Kei Nishioka; Yusuke Kimura; Yoshitaka Hata; Hirotaka Tsuru; Masafumi Wada; Yosuke Minoda; Xiaopeng Bai; Yoshihisa Shoguchi; Takayuki Nasu; Shuzaburo Nagatomo; Kazumasa Muta; Haruei Ogino; Yoshihiro Ogawa
Journal:  DEN open       Date:  2022-01-26
  2 in total