Literature DB >> 24845358

Spectral reproducibility and quantification of peptides in MALDI of samples prepared by micro-spotting.

Yong Jin Bae1, Kyung Man Park, Sung Hee Ahn, Jeong Hee Moon, Myung Soo Kim.   

Abstract

Previously, we reported that MALDI spectra of peptides became reproducible when temperature was kept constant. Linear calibration curves derived from such spectral data could be used for quantification. Homogeneity of samples was one of the requirements. Among the three popular matrices used in peptide MALDI [i.e., α-cyano-4-hydroxycinnamic acid (CHCA), 2,5-dihydroxybenzoic acid (DHB), and sinapinic acid (SA)], homogeneous samples could be prepared by conventional means only for CHCA. In this work, we showed that sample preparation by micro-spotting improved the homogeneity for all three cases.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24845358     DOI: 10.1007/s13361-014-0919-7

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  16 in total

1.  Homogeneous sample preparation for automated high throughput analysis with matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry.

Authors:  P Onnerfjord; S Ekström; J Bergquist; J Nilsson; T Laurell; G Marko-Varga
Journal:  Rapid Commun Mass Spectrom       Date:  1999       Impact factor: 2.419

Review 2.  Profiling and imaging proteins in tissue sections by MS.

Authors:  Pierre Chaurand; Sarah A Schwartz; Richard M Capriolo
Journal:  Anal Chem       Date:  2004-03-01       Impact factor: 6.986

3.  Automated MALDI matrix deposition method with inkjet printing for imaging mass spectrometry.

Authors:  Dodge L Baluya; Timothy J Garrett; Richard A Yost
Journal:  Anal Chem       Date:  2007-07-21       Impact factor: 6.986

Review 4.  Quantitative matrix-assisted laser desorption/ionization mass spectrometry.

Authors:  Mark W Duncan; Heinrich Roder; Stephen W Hunsucker
Journal:  Brief Funct Genomic Proteomic       Date:  2008-09

5.  Improving the signal intensity and sensitivity of MALDI mass spectrometry by using nanoliter spots deposited by induction-based fluidics.

Authors:  Tingting Tu; Andrew D Sauter; Andrew D Sauter; Michael L Gross
Journal:  J Am Soc Mass Spectrom       Date:  2008-04-08       Impact factor: 3.109

6.  Electrospray sample preparation for improved quantitation in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

Authors:  R R Hensel; R C King; K G Owens
Journal:  Rapid Commun Mass Spectrom       Date:  1997       Impact factor: 2.419

7.  Quantitative MALDI tandem mass spectrometric imaging of cocaine from brain tissue with a deuterated internal standard.

Authors:  David A Pirman; Richard F Reich; András Kiss; Ron M A Heeren; Richard A Yost
Journal:  Anal Chem       Date:  2012-12-24       Impact factor: 6.986

8.  Equilibrium conditions in laser-desorbed plumes: thermodynamic properties of alpha-cyano-4-hydroxycinnamic acid and protonation of amino acids.

Authors:  Gary R Kinsel; Daqing Yao; Faten H Yassin; Dennis S Marynick
Journal:  Eur J Mass Spectrom (Chichester)       Date:  2006       Impact factor: 1.067

9.  A comparative study of in- and post-source decays of peptide and preformed ions in matrix-assisted laser desorption ionization time-of-flight mass spectrometry: effective temperature and matrix effect.

Authors:  So Hee Yoon; Jeong Hee Moon; Myung Soo Kim
Journal:  J Am Soc Mass Spectrom       Date:  2010-08-07       Impact factor: 3.109

10.  Quantitative reproducibility of mass spectra in matrix-assisted laser desorption ionization and unraveling of the mechanism for gas-phase peptide ion formation.

Authors:  Sung Hee Ahn; Kyung Man Park; Yong Jin Bae; Myung Soo Kim
Journal:  J Mass Spectrom       Date:  2013-03       Impact factor: 1.982

View more
  1 in total

1.  Investigations of Some Liquid Matrixes for Analyte Quantification by MALDI.

Authors:  Jeong Hee Moon; Kyung Man Park; Sung Hee Ahn; Seong Hoon Lee; Myung Soo Kim
Journal:  J Am Soc Mass Spectrom       Date:  2015-06-30       Impact factor: 3.109

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.